We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
The aim of this study is to compare patient geometrical uncertainties in the treatment of breast boost three-dimensional conformal radiation therapy (3D-CRT) considering both manual alignment and automatic different registration methods in cone-beam computed tomography (CBCT).
Methods:
A total of 85 patients were chosen for this study. A total of 254 registrations of CBCT vs planning computed tomography (CT) were retrospectively performed using automatic registration algorithms from Elekta XVI system (Clipbox and Mask) to detect patient setup uncertainties. All CBCTs were also matched manually by three health professionals. Mean shift values obtained with manual registration performed by health professionals were used as reference. Absolute value of difference between automatic algorithm shifts and reference values shifts was collected for each enrolled patient considering the three different spatial directions (x,y,z), and the magnitude was calculated (δm for Mask and δc for Clipbox).
Results:
Data analysis showed a significant difference in δm and δc. t-Test statistics showed a high difference between Mask and Clipbox, in particular mean δm = (1.3 ± 0.1) mm and δc = (3.3 ± 1.2) mm (p-value <0.0001). Mask algorithm was performed in a very similar way with respect to the reference alignment, and the differences between these two procedures were of the order of 1 mm. Clipbox algorithm showed larger differences with manual registration.
Conclusions:
These results suggest that the Mask algorithm may be the optimal choice for patient setup verification in clinical practice for breast boost treatment in 3D-CRT.