Hostname: page-component-78c5997874-lj6df Total loading time: 0 Render date: 2024-11-17T16:16:53.659Z Has data issue: false hasContentIssue false

Hybrid MoM-circuit models to analyze the radiated susceptibility of multiconductor shielded cables within complex structures

Published online by Cambridge University Press:  10 August 2022

Zahra Bouzidi*
Affiliation:
Laboratory of Electrical Systems and Telecommunications, Faculty of Science and Technology, CADI AYYAD University, Marrakesh, Morocco
Mohamed Saih
Affiliation:
Laboratory of Automatic, Energy Conversion and Microelectronics, Faculty of Science and Technology, SULTAN MOULAY SLIMAN University, Beni Mellal, Morocco
Hicham Rouijaa
Affiliation:
Laboratory of Systems Analysis and Information Processing, Faculty of Science and Technology, HASSAN 1 University, Settat, Morocco
Abdelaziz El Idrissi
Affiliation:
Laboratory of Electrical Systems and Telecommunications, Faculty of Science and Technology, CADI AYYAD University, Marrakesh, Morocco
Abdelilah Ghammaz
Affiliation:
Laboratory of Electrical Systems and Telecommunications, Faculty of Science and Technology, CADI AYYAD University, Marrakesh, Morocco
*
Author for correspondence: Zahra Bouzidi, [email protected]
Rights & Permissions [Opens in a new window]

Abstract

This paper presents an analysis of the radiated susceptibility of multiconductor shielded cables within complex structures following a hybrid method using moments (MoM) circuit models. The MoM code was used to compute the currents on the shielding induced by an external electromagnetic field and incorporated into a circuit model. The proposed method can be employed for nonlinear loads. The method was tested on two cases: coaxial shielded cables inside a cavity and a car with complex wiring, including a coaxial cable, a twinax cable (a cable with two parallel wires), and a triaxial cable (a cable with three parallel wires), all of which are excited by an incident plane wave. The proposed method provides high accuracy and significant speed gain, and its results are in good agreement with those obtained in other studies.

Type
Electromagnetic Compatibility
Copyright
© The Author(s), 2022. Published by Cambridge University Press in association with the European Microwave Association

Introduction

Transmission lines are material structures serving as support for the propagation of electromagnetic (EM) fields that are associated with electrical signals. Transmission lines have at least two conductors, but they can take more complicated configurations. Many studies have examined the modeling and analysis of transmission lines. Several techniques and models have been used in this research work, such as the lumped-circuit approximate model, which enables the representation of the line in the form of a resistance, inductance, capacitance, and conductance RLCG-equivalent circuit model. This also applies to the analysis of multiconductor transmission lines (MTLs) [Reference Ho1], which complicates the equivalent circuit considerably. It causes oscillations to temporal responses and requires a large calculation time, which makes it useless. The method of characteristics, also called Branin's method [Reference Branin2], seeks to analyse an ideal transmission line by representing it in the form of a quadruple. The advantage of this quadruple form is that it does not presuppose load conditions applied at its ends (i.e. the loads at the ends of the line can be linear or not). The application of this approach is presented in detail in this paper. This model is limited to only lossless lines; whereas some other models in the literature can be used to study MTLs with low losses [Reference Maio, Canavero and Dilecce3] and with frequency-dependent losses [Reference Erdin, Dounavis, Achar and Nakhla4].

This paper presents an investigation of the immunity of a system to interference created by natural or industrial sources of disturbance, which is one of the many EM compatibility problems. These types of interference can create high voltages and currents in electronic cards placed in equipment and in wire links between equipment. To protect against these EM attacks, the traditional solution is shielding [Reference Liu, Yin, Tang, Liu, Mao and Liu5], which takes the form of a metal enclosure for electronic equipment or a circular sheath for wire connections. A technology related to the filtering cable, which also has the potential to improve the EM compatibility of the cable is proposed in [Reference Han, Liu, Lin, Cheng and Zhou6].

In recent years, the research field of shielded cables has become the subject of increasing interest. These cables are usually used in transport applications, power plants, wired communication networks, to protect the inner conductor from radiated interferences and conducted. However, due to the complex configuration of an electronic systems, including not only EM structures (cavities, apertures) but also wires, PCBs, and semiconductors, and because of its many coupling paths, including front-door and back-door couplings, the external EM wave interaction with an electronic system is a complex issue, one which will disturb this system.

Several numerical methods are developed to simulate a large electrical system. Those methods are considered the most efficient techniques, but they are complex and computationally demanding in terms of time and memory usage. Numerical EM modeling methods include finite-difference time domain methods (FDTD) [Reference Yee7, Reference Taflove8], MoM [Reference Roger9], finite element methods [Reference Silvster10], and the partial element equivalent circuit [Reference Wollenberg and Gorisch11]. These numerical methods are applied to three-dimensional (3D) EM analyses. However, some problems can be thoroughly analyzed using just two-dimensional (2D) analysis; for example, the Baum-Liu-Tesche equation [Reference Baum, Liu and Tesche12] and the simulation program with integrated circuit emphasis (SPICE) [Reference Xie, Wang, Fan and Liu13] models are often used to model EM propagation along cables, strip lines, microstrips, and more.

EM field coupling analysis of MTLs has been performed by many researchers. The challenge of those approaches is in modifying the telegrapher's classical equations by incorporating additional voltage and current sources to model the external excitation fields [Reference Taylor, Harrison and Satterwhite14, Reference Rachidi16]. The authors of [Reference Saih, Rouijaa and Ghammaz17] propose a circuit model of lossy coaxial shielded cables to analyze radiated and conducted susceptibilities with unmatched line loads. They used the Branin's model to obtain the voltage and current distributions. However, this model is limited to analyzing the radiated susceptibility of shielded unifilar cables. In this paper, we are interested in combining numerical and circuit EM analysis methods to create a hybrid method. We aim to explore their benefits through an analysis of the studied problem.

In recent years, considerable research has been conducted on hybrid methods, such as the method of moments-based iterative method [Reference Bayram and Volakis18], the hybrid FDTD SPICE method [Reference Xie, Wang, Fan and Liu13], the time-domain integral equation [Reference Bagci, Yilmaz, Jin and Michielssen19] method, and the hybrid finite difference-finite volume [Reference Ferrieres, Parmantier, Bertuol and Ruddle20] method. However, these methods have been used to evaluate only MTLs without shields. In reality, the shielded cables considered in this paper are usually used in wired communication systems to protect the signal transmission from external interference. Recently, the FDTD method has been proposed to obtain the transient EM responses of coaxial shielded cables in a complex structure, such as a metallic cabin with arbitrary thin slots [Reference Liu, Yin, Tang, Liu, Mao and Liu5] and metallic enclosures [Reference Wang, Yin, Fang and Liu21] excited by an EM pulse. However, nonlinear and time-varying loads cannot be handled with these models. It is difficult to study the responses at the terminators of the transmission lines that end with nonlinear loads because the response of the nonlinear loads is more complicated than that of linear ones.

In this paper, we present a fast, rigorous hybrid MoM circuit model to analyze the radiated susceptibility of multiconductor shielded cables (coaxial twinax cables) in complex structures. An MoM code is used to compute the currents on the shielding, which are induced by an external EM field and incorporated into a circuit model. This technique can be used to analyze nonlinear loads. The obtained results are analyzed and compared with those from other approaches.

This article is organized as follows. The theory of the hybrid MoM circuit model method used in this study is given in section “Theory of hybrid MoM circuit models”. In the section “Simulation results”, the simulation results obtained from applying the proposed hybrid approach are presented. Section “Conclusion” concludes this article and gives some future perspectives.

Theory of hybrid MoM circuit models

The principle of hybridization consists of dividing the entire system into two or more subsystems. Each subsystem is individually treated by the most suitable calculation code to reduce the calculation time. In the following sub-sections, we present with the hybridization approach that is used in our paper, the current recovery method. Then, we explore the excitation of multiconductor shielded cables by an incident EM field and discuss their excitation fields in a complex structure. Finally, we describe the circuit models of the inner wires.

Excitation of multiconductor shielded cables by an incident electromagnetic field

The transmission line equations for multiconductor shielded cables with perfect, infinite conducting and excited by an incident EM field, as shown in Fig. 1, can be written as follows:

Fig. 1. Coaxial shielded cable over a perfectly conducting ground.

Outer system

(1)$$\left\{\matrix{{\delta V_{shd}\over \delta z} + jwL_{shd}I_{shd} + R_{shd}I_{shd} = V_{FD}\cr\cr {\delta I_{shd}\over \delta z} + jwC_{shd}V_{shd} + G_{shd}V_{shd} = I_{FD}}\right.$$

Inner system

(2)$$\left\{\matrix{{\delta V_{wr}\over \delta z} + jwL_{wr}I_{wr} + R_{wr}I_{wr} & = Z_{t}I_{shd}\cr\cr {\delta I_{wr}\over \delta z} + jwC_{wr}V_{wr} + G_{wr}V_{wr} & = 0}\right.$$

where V shd and I shd are the shield-to-ground voltage and the current flowing between the external shield and the ground, respectively. G shd, R shd, L shd, and C shd represent the per-unit-length (PUL) conductance, resistance, inductance, and capacitance of the outer system, respectively.

V wr = [V wr1,  V wr2,  …V wrN] T and

I wr = [I wr1,  I wr2,  …I wrN] T are the line voltage and current vectors,respectively.

N×N matrices G wr, R wr, I wr, and C wr are the PUL conductance, resistance, inductance, and capacitance matrices of the inner system, respectively.

Z t = [Z t1,  Z t2,  …Z tN] T represents the transfer impedance vector. For the braided shield, the transfer impedance is given by the following equation [Reference Saih, Rouijaa and Ghammaz22]:

(3)$$Z_{tk} = Z_{dk} + jwL_{tk}$$

where Z dk and L tk represent the diffusion term and the inductance, respectively, which indicates the effect of the field penetrating through the braid apertures, respectively. The expression of these two parameters is derived from[Reference Wang, Yin, Fang and Liu21]. For simplicity, the transfer impedance Z tk is expressed as [Reference Saih, Rouijaa and Ghammaz23]:

(4)$$Z_{tk} = R_{dk} + jwL_{tk}$$

where R dk is the constant PUL transfer resistance of the shield relative to the k th wire.

V FD and I FD are the distributed voltage and current sources; they represent the effects of the incident fields and are computed based on the components of the incident magnetic and electric fields (for further details, see [Reference Caniggia and Maradei24]).

Excitation fields of multiconductor shielded cables in a complex structure

To analyze multiconductor shielded cables within a complex structure, such as an automobile or a cavity excited by a nonuniform incident wave, as shown in Fig. 2(a), the line must be discretized into cells; the length of each cell is ΔZ = λ/10. A currents recovery method is used to compute the current of the shield in each segment I shdi. Currents are needed to compute the terminal voltages and currents of the wires, as expressed in equation (2).

Fig. 2. (a) Multiconductor shielded cables inside a cavity with slot excited by an external plane wave field. (b) The configuration composed of a cavity with slot and shield only used to compute the current of the shield in each segment by MoM. (c) The configuration composed by inner wires used to compute the terminal voltages and currents after incorporating currents of the shield for each cell.

Currents recovery method

The first subsystem of the proposed hybrid method consists of the structure and shielding, as shown in Fig. 2(b), which are processed using a 3D method. In our application, we use the 3D MoM; this digital approach has been implemented in the commercial software FEKO. The objective is to recover the current in the shielding as a function of the frequency. The second subsystem is made up of inner wires, which are processed by a line theory-type code (Fig. 2(c)). In our application, we use Branin's model. We recover the current in the shielding generated using FEKO to insert it into the Branin model.

Note that, because it is necessary to identify only currents of the shield, the inner wires do not have to be meshed; consequently, the meshes are smaller than those used with only 3D MoM code. The currents of the shield I shd for each cell are saved in data files and incorporated into an equivalent circuit model, which is used to compute the terminal voltages and currents of the inner system.

Circuit models of the inner wires

Equation (2) consists of coupled sets of partial differential equations. Here, a similar transformation is needed to decouple them into modal voltages V wrm and currents I wrm[Reference Ferrieres, Parmantier, Bertuol and Ruddle20].

(5)$$\left\{\matrix{{ V_{wr}} = T_{V}V_{wrm}\cr {I_{wr}} = T_{I}I_{wrm}}\right.$$

Substituting (5) in (2), yields

(6)$$\left\lbrace \matrix{{\delta\over \delta z}V_{wrm} + jwL_{wrm}I_{wrm} + R_{wrm}I_{wrm} = T^{-1}_{v}Z_{t}I_{shd} \cr {\delta\over \delta z}I_{wrm} + jwC_{wrm}V_{wrm} + G_{wrm}V_{wrm} = 0\hfill\cr }\right.$$

where

(7a)$$L_{wrm} = T^{-1}_{V}L_{wr}T_{I}$$
(7b)$$C_{wrm} = T^{-1}_{I}C_{wr}T_{V}$$
(7c)$$R_{wrm} = T^{-1}_{V}R_{wr}T_{I}$$
(7d)$$G_{wrm} = T^{-1}_{I}G_{wr}T_{V}$$

and where T I and T V represent the voltage and current transformation matrices, respectively. T I and T V are chosen in order to simultaneously diagonalize both L wr and C wr. From (6), the relation between the terminal mode voltages and currents for each cell can be written as follows [Reference Saih, Rouijaa and Ghammaz22]:

(8)$$\left\lbrace \matrix{V_{rm} = V_{rwm}( z_{0}) -Z_{cm}I_{wrm}( z_{0}) \hfill\cr V_{im} = V_{m}( z_{0} + \Delta z) + Z_{cm}I_{wrm}( z_{0} + \Delta z) }\right.$$
(9)$$\left\lbrace \matrix{V_{rm} = e^{-\gamma_m\Delta z}[ V_{rwm}( z_{0} + \Delta z) -Z_{cm}I_{wrm}( z_{0} + \Delta z) \cr -T^{-1}_V Z_t I_{sdh}( z_0 + \Delta z) ] \cr { V_{im}} = e^{-\gamma_m\Delta z}[ V_{rwm}( z_{0}) + Z_{cm}I_{wrm}( z_{0}) ] \cr \quad + T^{-1}_V Z_t I_{sdh}( z_0 + \Delta z) }\right.$$

where Z cm and γm are the mode characteristic impedances and propagation constants, respectively. They are given by the following equations:

(10)$$Z_{cw} = \sqrt{{R_{wrm} + jwL_{wrm}\over G_{wrm} + jwC_{wrm}}}$$

γm = αw + jβw

(11)$$\gamma_{m} = \sqrt{( R_{wrm} + jwL_{wrm}) ( G_{wrm} + jwC_{wrm}) }$$

Ignoring the PUL conductance G wrm and using the first term of the Taylor series expansion, we obtain the following equations:

(12)$$Z_{cw} = \sqrt{{R_{wrm} + jwL_{wm}\over jwC_{wm}}} = R_{cm} + {1\over jwC_{cm}}$$

where $R_{cm} = \sqrt {{L_{wrm}\over C_{wrm}}}$ and $C_{cm} = {2L_{wrm}\over R_{wrm}R_{cm}}$

(13)$$\gamma_{m} = \alpha_w + j\beta_w = {R_{wrm}\over 2R_{cm}} + jw\sqrt{L_{wrm}C_{wrm}}$$

In this case, the characteristic impedance can be viewed as resistance and capacity connected in series. From (8), (9), and (12), we can deduce the equivalent circuit presented in Fig. 3. From (5), the terms of the generators controlled voltage and current placed in each cell can be obtained by the following equations:

(14)$$V_{wr}( z,\; t) _i = \sum_{k = 1}^N[ T_V] _{ik}V_{wm}( z,\; t) _k$$
(15)$$I_{wrm}( z,\; t) _i = \sum_{k = 1}^N[ T^{-1}_I] _{ik}I_{wr}( z,\; t) _k$$

Fig. 3. Equivalent circuit of inner wires obtained from the method of characteristics (Branin's method) [Reference Bayram and Volakis18] as implemented in ESACAP [Reference Saih, Rouijaa and Ghammaz22].

Simulation results

In this section, we analyze the simulation results obtained by the proposed hybrid approach. First, we analyze the radiated susceptibility of coaxial cables, followed by the radiated susceptibility of coaxial cables in the presence of a trough and an automobile.

Analysis of the radiated susceptibility of coaxial cables

Figure 4 shows the configuration of the radiated susceptibility analyzed to study the validity of the hybrid MoM circuit models method. The configuration consists of a coaxial shielded cable, which consists of an inner solid wire (R w = 5 mm) and a shield with an interior radius R S of 2.5 mm, over a perfectly conducting ground. The line length is 1 m, and the conductors are suspended 5 m above a ground plane. The relative permittivity ɛr of the inner insulation equals 2.375.

Fig. 4. Coaxial shielded cable over a perfectly conducting ground.

The constant PUL transfer resistance R T and the transfer inductance L T are 100 mΩ/m and 0.5 nH/m, respectively. The shield is grounded at both ends with terminations impedances R sh1 = 1 MΩ and R sh2 = 154.365Ω, while the inner terminations are matched: R w1 = R w2 = 50Ω. The coaxial cable is excited by an incident plane wave oriented along the x axis of amplitude E = 1V/m and propagating along z axis (E x − k z).

Figure 5 illustrates the amplitude evolution of the wire-to-shield voltage at the far end as a function of frequency, which is obtained by the proposed hybrid method, together with the outcomes determined by the MoM. The results obtained by our method are in excellent agreement with those obtained by the MoM method, which confirms the validity of the proposed hybrid method approach.

Fig. 5. Wire to shield voltage of the coaxial cable at the far end.

The two curves depicted in this figure have two characteristic parts corresponding to the low frequency domain (assumption of short lines: length < <λ wavelength) and high frequencies (long line). In the first part of the curves, the voltages are proportional to the transfer impedance Z t [Reference Degauque and Hamelin28]. The second part is characterized by anti-resonances specific to the propagation phenomenon.

The shielding is short-circuited on the right (Z 2 = 0.5Ω). Figure 6 illustrates the induced current in dBA on shielded cables excited by uniform Ex-Kz, which is obtained by the hybrid model. Comparing these with the analytical results published by Smith [Reference Smith27] shown in Fig. 7 shows exact agreement between the results of the hybrid and analytic methods.

Fig. 6. Result of the induced current in dBA, on shielded cable excited by uniform Ex-Kz, computed with ESACAP.

Fig. 7. Solution for the induced current on shielded cable excited by uniform Ex-Kz [Reference Smith27].

Analysis of the radiated susceptibility of coaxial cable in the presence of a trough

To validate the proposed hybrid method in complex structures, we consider a coaxial shielded cable similar to that depicted in Fig. 4 in the presence of a trough. The length L g, width W g, and height H g of the trough are 2, 0.2, and 0.2 m, respectively, as shown in Fig. 8. The entire structure is excited by an incident plane wave oriented along the x-axis and propagated along the z-axis (E x − k z) with an amplitude of E = 1 V/m.

Fig. 8. Coaxial shielded cable in the vicinity of a trough excited by an external plane wave field.

The wire-to-shield voltage at the far end of the coaxial cable obtained by the proposed approach is given in Fig. 9. The results obtained by our method are in excellent accord with those obtained by the MoM method, which validates the use of the hybrid method in complex structures.

Fig. 9. Wire-to-shield voltage of the coaxial cable at the far end.

Table 1 compares the computing time needed in the two methods. This shows that the MoM method requires significantly more computing time, than the hybrid method. Because the inner wires must not mesh while computing the shields currents, they are not meshed when using the hybrid method.

Table 1. Needed time by the hybrid method and MoM

Analysis of the radiated susceptibility of coaxial cables in the presence of an automobile

Figure 10 shows that the complex wiring inside a car, illuminated by an incident plane wave oriented along the x-axis and propagated along the z-axis (E x − k z), has an amplitude of E = 1 V/m. The wiring consists of three shielded cables: C 1, a coaxial cable; C 2, shielded cables with two parallel wires (i.e. twinax cable); and C 3, shielded cables with three parallel wires (i.e. triaxial cable).

Fig. 10. Three shielded cables within a car excited by an external plane wave field.

The lengths of shielded cables C 1, C 2, and C 3 are L C1 = 0.5 m, L C2 = 0.4 m, and L C3 = 0.5 m respectively. All the cables have the same height, h = 5 mm. The characteristics of the shielded cables can be defined in terms of the shield radius R s, the inner wire radius R w, and the interval between wires d (the values of which are reported in Table 2). The transfer impedances and load networks with the adopted values are given in Table 3.

Table 2. Parameters of shielded cables

Table 3. Electrical parameters of lines configuration shown in Fig. 8

The voltages calculated using the proposed method at the far end in the frequency analysis are illustrated in Fig. 11. It can be observed that the lines resonate at f = n × (3 × 108 4/λ), n = 1,  3,  5 (f1 = 75 MHz, f2 = 225 MHz, and f3 = 375 MHz). The magnitudes of these induced voltages can reach − 70 V.

Fig. 11. Three shielded cables within a car excited by an external plane wave field.

Conclusion

This paper presented a hybrid MoM circuit model of the analysis of the radiated susceptibility for lossy multiconductor shielded cables. The advantage of this method is its applicability for nonuniform transmission lines with nonlinear loads. The proposed hybrid method also requires a much smaller amount of computation time than other numerical methods. This paper has described the proposed technique in detail. The method's validity was confirmed by comparing its results with those derived by other methods. It is easy to extend the proposed models to multiconductor shield cables within a complex structure excited by a non-uniform incident wave (e.g. antennas). We will discuss this question in future papers.

Zahra Bouzidi obtained his diploma in electrical engineering from Cadi Ayyad University Morocco in 2016. He is a research member of the Electrical Systems and Telecommunications Laboratory (LSEEET) and preparing his doctorate thesis. His research interests include electromagnetic compatibility and multiconductor transmission lines.

Mohamed Saih is a professor of physics, attached to Sultan Moulay Slimane University, Beni Mellal, Morocco. He obtained his Ph.D. thesis on “Modeling of Multiconductor Transmission Lines Within Complex Structures”. He is an associate member of Automatic, Energy Conversion and Microelectronics Laboratory. His research interests include electromagnetic compatibility, multiconductor transmission lines, numerical electromagnetic methods, and antenna designs.

Hicham Rouijaa is a professor of physics, attached to Hassan 1 University, Settat, Morocco. He obtained his Ph.D. thesis on ”Modeling of Multiconductor Transmission Lines using Pade Approximant Method: Circuit Model” in 2004 from Aix Marseille University, France. He is an associate member of the Systems Analysis and Information Processing Laboratory at Hassan 1 University. His current research interests concern electromagnetic compatibility and multiconductor transmission lines.

Abdelaziz El Idrissi received the Doctor of Instrumentation and Measurement degree from Bordeaux 1 University, France, in 1993. Since 1994, he has been a professor at the Faculty of Sciences and Technologies, Cadi Ayyad University of Marrakech, Morocco and he is a actual member of the Electrical Systems and Telecommunications Laboratory (LSEEET) at Cadi Ayyad University. His research interests include electronic instrumentation, antennas, and transmission lines.

Abdelilah Ghammaz received the Doctor of Electronic degree from the National Polytechnic Institute (ENSEEIHT) of Toulouse, France, in 1993. In 1994, he went back to Cadi Ayyad University in Marrakech, Morroco. Since 2003, he has been a professor at the Faculty of Sciences and Technology, Marrakech, Morroco. He is a member of the Electrical Systems and Telecommunications Laboratory (LSEEET) at Cadi Ayyad University. His research interests are in the field of electromagnetic compatibility, multiconductor transmission lines, telecommunications, and antennas.

References

Ho, CW (1973) Theory and computer-aided analysis of lossless transmission lines. IBM Journal of Research and Development 17, 249255.CrossRefGoogle Scholar
Branin, FH (1967) Transient analysis of lossless transmission lines. Proceedings of the IEEE 55, 20122013.10.1109/PROC.1967.6033CrossRefGoogle Scholar
Maio, I, Canavero, FG and Dilecce, B (1996) Analysis of crosstalk and field coupling to lossy MTLs in a SPICE environment. IEEE Transactions on Electromagnetic Compatibility 38, 221229.10.1109/15.536050CrossRefGoogle Scholar
Erdin, I, Dounavis, A, Achar, R and Nakhla, MS (2001) A SPICE model for incident field coupling to lossy multiconductor transmission lines. IEEE Transactions on Electromagnetic Compatibility 43, 485494.CrossRefGoogle Scholar
Liu, Q, Yin, W, Tang, M, Liu, G, Mao, J and Liu, Q (2009) Time-domain investigation on cable-induced transient coupling into metallic enclosures. IEEE Transactions on Electromagnetic Compatibility 51, 953962.10.1109/TEMC.2009.2029347CrossRefGoogle Scholar
Han, Y, Liu, Z, Lin, Y, Cheng, C and Zhou, Y (2022) Dual-band bandstop filtering cable design using defected conductor layer with asymmetric spiral structure. IEEE Transaction on Microwave Theory Technology 70, 31543162.10.1109/TMTT.2022.3157855CrossRefGoogle Scholar
Yee, K (1966) Numerical solution of initial boundary value problems involving Maxwell's equations in isotropic media. IEEE Transactions on Antennas and Propagation 14, 302307.Google Scholar
Taflove, A (2005) Computational Electrodynamics: The Finite-Difference Time-Domain Method, 3rd Edn. Boston: Artech House.Google Scholar
Roger, F (1993) Field Computation by Moment Methods IEEE Press Series on Electromagnetic Wave Theory. Hardcover – Import, 21 April 1993. New York: Harrington.Google Scholar
Silvster, P (1973) Finite element analysis of planar microwave networks. IEEE Transactions on Microwave Theory and Techniques 21, 104108.CrossRefGoogle Scholar
Wollenberg, G and Gorisch, A (1999) Coupling of PEEC models with transmission line models for simulation of wiring structures, electromagnetic compatibility. 1999 IEEE International Symposium on (Volume 2), pp. 848–853.Google Scholar
Baum, C, Liu, T and Tesche, F (1978) On the analysis o f general multiconductor transmission-line networks, Kirtland Air Force Base. Albuquerque, NM, Interaction Note 350.Google Scholar
Xie, H, Wang, J, Fan, R and Liu, Y (2009) A hybrid FDTD-SPICE method for transmission lines excited by a nonuniform incident wave. IEEE Transactions on Electromagnetic Compatibility 51, 811817.10.1109/TEMC.2009.2020913CrossRefGoogle Scholar
Taylor, C, Harrison, C and Satterwhite, R (1965) The response of a terminated twowire transmission line excited by a nonuniform electro-magnetic field. IEEE Transactions on Antennas and Propagation 13, 987989.10.1109/TAP.1965.1138574CrossRefGoogle Scholar
Agrawal, A, Price, H and Gurbaxani, S (1980) Transient response of multiconductor transmission lines excited by a nonuniform electromagnetic field. IEEE Transactions on Electromagnetic Compatibility EMC-22, 119129.10.1109/TEMC.1980.303824CrossRefGoogle Scholar
Rachidi, F (1993) Formulation of field to transmission line coupling equations in terms of magnetic excitation field. IEEE Transactions on Electromagnetic Compatibility 35, 404407.CrossRefGoogle Scholar
Saih, M, Rouijaa, H and Ghammaz, A (2017) Circuit models of lossy coaxial shielded cables to analyze radiated and conducted susceptibilities with unmatched line loads. Journal of Microwaves, Optoelectronics and Electromagnetic Applications 16, 351362.10.1590/2179-10742017v16i2670CrossRefGoogle Scholar
Bayram, Y and Volakis, JL (2005) A generalized MoM SPICE iterative technique for field coupling to multiconductor transmission lines in presence of complex structures. IEEE Transactions on Electromagnetic Compatibility 47, 234246.10.1109/TEMC.2005.847393CrossRefGoogle Scholar
Bagci, H, Yilmaz, AE, Jin, JM and Michielssen, E (2007) Fast and rigorous analysis of EMC/EMI phenomena on electrically large and complex cable-loaded structures. IEEE Transactions on Electromagnetic Compatibility 49, 361381.10.1109/TEMC.2007.897159CrossRefGoogle Scholar
Ferrieres, X, Parmantier, JP, Bertuol, S and Ruddle, AR (2004) Application of a hybrid finite difference/finite volume method to solve an automotive EMC problem. IEEE Transactions on Electromagnetic Compatibility 46, 624634.10.1109/TEMC.2004.837837CrossRefGoogle Scholar
Wang, J, Yin, WY, Fang, JP and Liu, QF (2010) Transient responses of coaxial cables in an electrically large cabin with slots and windows illuminated by an electromagnetic pulse. Progress In Electromagnetics Research 106, 116.CrossRefGoogle Scholar
Saih, M, Rouijaa, H and Ghammaz, A (2016) Circuit models of multiconductor shielded cables:incident plane wave effect. International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 29, 243254.Google Scholar
Saih, M, Rouijaa, H and Ghammaz, A (2013) Crosstalk reduction by adaptation of shielded cables, International Conference on Intelligent Information and Network Technology, Settat morocco.Google Scholar
Caniggia, S and Maradei, F (2004) SPICE-like models for the analysis of the conducted and radiated immunity of shielded cables. IEEE Transactions on Electromagnetic Compatibility 46, 606616.10.1109/TEMC.2004.837841CrossRefGoogle Scholar
Paul, C (2006) Introduction to Electromagnetic Compatibility (Wiley Series in Microwave and Optical Engineering), 2nd Edn. Wiley-Interscience, New Jersey, 1016 p. ISBN-13: 978-0-471-75500-5.Google Scholar
Inzoli, L and Rouijaa, H (2001). Emcap2000 Esacap software. Applications handbook and users manual.Google Scholar
Smith, A (1977) Coupling of External Electromagnetic Fields to Transmission Lines. New York: Wiley.Google Scholar
Degauque, P and Hamelin, J (1990) Compatibilité électromagnétique. Edition Dunod. Paris, FranceGoogle Scholar
Figure 0

Fig. 1. Coaxial shielded cable over a perfectly conducting ground.

Figure 1

Fig. 2. (a) Multiconductor shielded cables inside a cavity with slot excited by an external plane wave field. (b) The configuration composed of a cavity with slot and shield only used to compute the current of the shield in each segment by MoM. (c) The configuration composed by inner wires used to compute the terminal voltages and currents after incorporating currents of the shield for each cell.

Figure 2

Fig. 3. Equivalent circuit of inner wires obtained from the method of characteristics (Branin's method) [18] as implemented in ESACAP [22].

Figure 3

Fig. 4. Coaxial shielded cable over a perfectly conducting ground.

Figure 4

Fig. 5. Wire to shield voltage of the coaxial cable at the far end.

Figure 5

Fig. 6. Result of the induced current in dBA, on shielded cable excited by uniform Ex-Kz, computed with ESACAP.

Figure 6

Fig. 7. Solution for the induced current on shielded cable excited by uniform Ex-Kz [27].

Figure 7

Fig. 8. Coaxial shielded cable in the vicinity of a trough excited by an external plane wave field.

Figure 8

Fig. 9. Wire-to-shield voltage of the coaxial cable at the far end.

Figure 9

Table 1. Needed time by the hybrid method and MoM

Figure 10

Fig. 10. Three shielded cables within a car excited by an external plane wave field.

Figure 11

Table 2. Parameters of shielded cables

Figure 12

Table 3. Electrical parameters of lines configuration shown in Fig. 8

Figure 13

Fig. 11. Three shielded cables within a car excited by an external plane wave field.