Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

The meridian circle installed at the Tokyo Astronomical Observatory in 1982/83 is equipped with a photoelectric Double Slit Micrometer which is one of the basic prerequisites for fully automatic observation. A slit plate is located in the image field of the telescope. It oscillates parallel to right ascension while being guided at the mean traveling speed of the star.

The paper describes the procedure by which the moment of the star passage through the instrument's meridian and declination is determined. Furthermore, the autocollimation devices are described which are an essential prerequisite for the determination and periodical checking of the instrumental errors.

Also, the measuring devices for the passage of the sun and the moon are dealt with briefly.

Type
V. Small Field Photoelectric Astrometry
Copyright
Copyright © Reidel 1986 

References

Literature

Kühne, C. 1983, A new automatic meridian circle PMC 190, Astron. Astrophys. 121, pp. 165173 Google Scholar
Høg, E., 1970, A Theory of a Photoelectric Micrometer Astron. Astrophys. 4, pp. 8995 Google Scholar
Yoshizawa, M., Yasuda, GH. 1982, Pinhole System for Solar and Lunar Observations, Annals of the Tokyo Astronomical Observatory, 2. Series, Vo. XIII, No. 4 Google Scholar