Residual Stress And Lattice Distortion Mapping Of Patterned Devices Which Failed Electromigration Testing Using The Microbeam X-Ray Diffraction (MXRD) Technique

Published online by Cambridge University Press:  15 February 2011

B. R. York
Affiliation:
IBM Materials Laboratory, 5600 Cottle Rd., San Jose CA., 95193
H. L. Pfizenmayer
Affiliation:
Motorola Semiconductor, 5005 E. McDowell Rd. Phoenix AZ., 85008
C. H. Lee
Affiliation:
Motorola Semiconductor, 5005 E. McDowell Rd. Phoenix AZ., 85008
R. O. Carnes
Affiliation:
Motorola Semiconductor, 5005 E. McDowell Rd. Phoenix AZ., 85008
Get access

Abstract

Spatially resolved residual stress and lattice distortion measurements have been made or experimental RF NPN devices which failed electromigration testing. The experimental devices underwent a steady state long term life test for 38272 hours at a die temperature of 100 degrees Celsius and device emitter currents of 100 mA. Residual stress contour maps of the Au interconnect metallurgy of these patterned devices were constructed with spatial resolution approaching 13 microns. The stress contour maps clearly show areas of the Au interconnect emitter lines, approximately 17 microns wide, which buckled when the local stresses exceeded the adhesion limits of these films. A stress gradient was observed going along the Au line from the emitter to the wire bonded pad which went from slightly compressive near the emitter to tensile approaching the wire bonded lead, and consistent with electromigration failures. In addition, lattice distortions as determined by integral line breadths, which were least square fitted by a gaussian*orentzian convolution of the instrument function, show a large continuous increase along the Au interconnect line in going from the emitter to the wire bond pad. The data was acquired using a 4-circle x-ray diffractometer which was specifically constructed to study electromigration issues in-situ. The diffractometer has a very low sphere of confusion (< 5 microns) and is equipped with tapered glass capillary optics, a mechanical, electrical, and thermal stressing stage and various energy dispersive (EDX) or position sensitive (PSD) detectors.

Type
Research Article
Copyright
Copyright © Materials Research Society 1996

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Goldsmith, C., Walker, G., Adv. in X-ray Analysis, 29, 1979 Google Scholar
2. The idea was first introduced by Jentzsch and Nahring in 1931 and later applied in the early 1950's to 1960's by a number of authors see, X-ray Diffraction of Polycrystalline Materials (eds. Peiser, Rooksby, Wilson-Chapman and Hall, London 1960, ch. 11)Google Scholar
3. York, B. R., Proceedings of ann. EMSA/MAS, 1992 Google Scholar
4. York, B. R., Proceedings of ann. EMSAMAS, 1994 Google Scholar
5. Noyan, I.C., Huang, T.C., and York, B.R., Critical Reviews in Solid State and Materials Science, 20(2): 125177(1995)Google Scholar
6. York, B. R. (to be published)Google Scholar