Hostname: page-component-78c5997874-s2hrs Total loading time: 0 Render date: 2024-11-05T12:53:15.151Z Has data issue: false hasContentIssue false

Performance Characteristics of Cdte Gamma-Ray Spectrometers

Published online by Cambridge University Press:  21 February 2011

Michael R. Squillante
Affiliation:
Radiation Monitoring Devices, Inc., 44 Hunt Street, Watertown, MA 02172
Herbert Cole
Affiliation:
Radiation Monitoring Devices, Inc., 44 Hunt Street, Watertown, MA 02172
Peter Waer
Affiliation:
Radiation Monitoring Devices, Inc., 44 Hunt Street, Watertown, MA 02172
Gerald Entine
Affiliation:
Radiation Monitoring Devices, Inc., 44 Hunt Street, Watertown, MA 02172
Get access

Abstract

The use of cadmium telluride (CdTe) semiconductor nuclear detectors is continuing to expand into new areas because of their unique properties which include room temperature operation and high detection efficiency. In addition, they remain the material of choice in many critical applications such as nuclear medicine and power plant monitoring because of their reputation for reliability and long term stability1. CdTe is by far the most developed of the compound semiconductors used in nuclear detector applications and it offers a number of significant benefits to researchers, clinicians and engineers who have special requirements relating to size, sensitivity and operating temperature.

Recently, there have been improvements in the growth of the crystalline material and in the fabrication procedures which have resulted in better performance and in the ability to produce arrays. This article describes the physical and electronic properties of CdTe nuclear detectors, discusses how the crystal growth and device fabrication procedures can affect these properties, and compares the performance to CdZnTe detectors.

Type
Research Article
Copyright
Copyright © Materials Research Society 1993

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1 Squillante, M.R., Entine, G., Nucl. Inst. and Methods, A322, 569 (1992)Google Scholar
2 Brelant, S., Elliott, M., Entine, G., Hsu, S., Revue de Physique Appliquee (Strassburg France), 141 (1977)Google Scholar
3 Shah, K.S., Lund, J.C., Olschner, F., IEEE Trans. Nucl. Sci., NS–37, 183 (1990).Google Scholar
4 Butler, J.F., Lingren, C.L., Doty, F.P., IEEE Trans. Nucl. Sci., NS–39, 129 (1992).Google Scholar
5 Malm, H.L., Martini, M., Can, J. Phys., 51, 2536 (1973).Google Scholar
6 Serreze, H.B., Entine, G., Bell, R.O., Wald, F.V., IEEE Trans. Nucl. Sci., NS–21, 404 (1974).Google Scholar