Hostname: page-component-586b7cd67f-gb8f7 Total loading time: 0 Render date: 2024-11-29T09:39:09.133Z Has data issue: false hasContentIssue false

Two Dimensional Amorphous Silicon Image Sensor Arrays

Published online by Cambridge University Press:  15 February 2011

R. A. Street
Affiliation:
Xerox Palo Alto Research Center, Palo Alto, CA 94304
X. D. Wu
Affiliation:
Xerox Palo Alto Research Center, Palo Alto, CA 94304
R. Weisfield
Affiliation:
Xerox Palo Alto Research Center, Palo Alto, CA 94304
S. Ready
Affiliation:
Xerox Palo Alto Research Center, Palo Alto, CA 94304
R. Apte
Affiliation:
Xerox Palo Alto Research Center, Palo Alto, CA 94304
M. Nguyen
Affiliation:
Xerox Palo Alto Research Center, Palo Alto, CA 94304
P. Nylen
Affiliation:
Xerox Palo Alto Research Center, Palo Alto, CA 94304
Get access

Abstract

Large two dimensional amorphous silicon image sensor arrays offer a new approach to electronic document input and x-ray imaging. The sensor array technology is now capable of image capture at greater than 10 frames/sec and with resolution of 200–400 spi. We describe our new high resolution imaging system, comprising a page-sized sensor array with nearly 3 million pixels, and the accompanying high speed read out and processing electronics. The key technological issues of pixel resolution, sensor fill factor, leakage currents and noise are reviewed. Measurements of a new array architecture are described, in which the sensor is formed as a single continuous film on top of the matrix addressing components.

Type
Research Article
Copyright
Copyright © Materials Research Society 1995

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Street, R. A., Nelson, S., Antonuk, L. and Perez-Mendez, V., MRS Symp. Proc. 192, 441 (1990).Google Scholar
2. Perez-Mendez, V., Cho, G., Drewery, J., Jing, T., Kaplan, S. N., Qureshi, S., Wildermuth, D., J. Non-Cryst. Solids., 137&138, 1291 (1991).Google Scholar
3. Antonuk, L. E., Boudry, J., Huang, W., McShan, D. L., Morton, E. J., Yorkston, J., Longo, M. J. and Street, R. A., Medical Physics, 19, 1455 (1992).Google Scholar
4. Powell, M. J., French, I. D., Hughes, J. R., Bird, N. C., Davies, O. S., Glasse, C and Curran, J. E., MRS Symp Proc., 258, 1127 (1992).Google Scholar
5. Kobayashi, K., Makida, S., Sato, Y., Hamano, T., Charge Coupled Devices and Solid State Optical Sensors III, SPIE Proc., 1900, 40 (1993).Google Scholar
6. Street, R. A. and Antonuk, L. E., IEEE Trans., Circuits and Devices, 9, 39 (1993).Google Scholar
7. Antonuk, L. E., Boudry, J., Kim, C. W., Morton, E. J., Yorkston, J., and Street, R. A., Medical Imaging V: Imaging Physics, SPIE Proc., 1443, 108, 1991;Google Scholar
Antonuk, L. E., Boudry, J., Huang, W., Lam, K. L., Morton, E. J., Ten Haken, R. K., Yorkston, J. and Clinthorne, N., IEEE Trans, on Medical Imaging, 13, 482 (1994).Google Scholar
8. Perez Mendez, V., Cho, G., Drewery, J., Fujieda, I., Kaplan, S. N., Qureshi, S. and Street, R. A., in Amorphous and Microcrystalline Semiconductors, edited by Kanicki, J. (Artech house, Boston, 1991), p 297.Google Scholar
9. Wu, J., Street, R. A., Weisfield, R. L., Nelson, S., Young, M., Nguyen, M. and Nylen, P., Charge Coupled Devices and Solid State Optical Sensors IV, SPIE Proc., 2172, 144 (1994).Google Scholar
10. Street, R. A., Wu, X. D., Weisfield, R. L., Nelson, S. and Nylen, P., MRS Symp Proc., 336, 873 (1994).Google Scholar
11. Street, R. A., Weisfield, R. L., Nelson, S. and Chang, R., Charge Coupled Devices and Solid State Optical Sensors III, SPIE Proc., 1900, 135 (1993).Google Scholar
12. Yorkston, J., Antonuk, L. E., Seraji, N., Huang, W., Siewerdsen, J. and El-Mohri, Y, Medical Imaging, SPIE Proc., 2163, 141 (1994);Google Scholar
Yorkston, J., Antonuk, L. E., El-Mohri, Y., Huang, W., Seraji, N. and Siewerdsen, J., Proc SPIE Medical Imaging conference (1995) in press.Google Scholar
13. Mei, P., Boyce, J. B., Hack, M., Lujan, R., Ready, S. E., Fork, D. K., Johnson, R. I. and Anderson, G. B., J. Appl. Phys., 76, 3194, 1994).Google Scholar
14. Street, R. A., Philos. Mag. B 63, 1343, (1991)Google Scholar
15. Street, R. A., Fujieda, I., Weisfield, R. L., Nelson, S. and Nylen, P., MRS Symp Proc., 258, 1145 (1992).Google Scholar
16. Ross, S., Naday, I., Kanyo, M., Westbrook, M. L., Westbrook, E. M., Phillips, W. C., Stanton, M. J. and Street, R. A., Charge Coupled Devices and Solid State Optical Sensors V, SPIE Proc., 2415, 189 (1995)Google Scholar
17. Fuiieda, I., Street, R. A., Weisfield, R. L., Nelson, S., Nylen, P., Perez Mendez, V. and Cho, G., Jpn. J. Appl. Phys., 32, 198 (1993).Google Scholar
18. Schiebel, U., Conrads, N., Jung, N., Weibrecht, M., Wieczorek, H., Zaengel, T., Powell, M. J., French, I. D. and Glasse, C., Medical Imaging, SPIE Proc., 2163, 129 (1994).Google Scholar
19. Street, R. A., Weisfield, R. L., Nelson, S. Nylen, P. and Wu, X. D., MRS Symp Proc., 297, 957 (1993).Google Scholar
20. Fujieda, I., Cho, G, Kaplan, S. N., Perez-Mendez, V., Qureshi, S. and Street, R. A., J. Non-Cryst. Solids, 115, 174 (1989).Google Scholar
21. Zhao, W., and Rowlands, J. A., Medical Imaging VI: Instrumentation, SPIE Proc., 1651, 134 (1992).Google Scholar
22. Lee, D. L., Jeromin, L. S. and Cheung, L. K., Proc. SPIE Medical Imaging conference (1995) in press.Google Scholar
23. Jackson, W. B., private communication.Google Scholar
24. Graeve, T., Huang, E.W., Alexandert, S. M. and Li, Y., Proc. SPIE Medical Imaging conference (1995) in press.Google Scholar