No CrossRef data available.
Article contents
A New Solution of Non-integrated Correlative Light and Electron Microscopy Based on High-vacuum Optical Platform
Published online by Cambridge University Press: 25 July 2016
Abstract
Correlative light and electron microscopy (CLEM) offers a means of guiding the search for the unique or rare events by fluorescence microscopy (FM) and allows electron microscopy (EM) to zoom in on them for subsequent EM examination in three-dimensions (3D) and with nanometer-scale resolution. FM visualizes the localization of specific antigens by using fluorescent tags or proteins in a large field-of-view to study their cellular function, whereas EM provides the high level of resolution for complex structures. And cryo CLEM combines the advantages of maintaining structural preservation in a near-native state throughout the entire imaging process and by avoiding potentially harmful pre-treatments, such as chemical fixation, dehydration and staining with heavy metals. Besides for frozen-hydrated biological samples, CLEM combines the advantages of a close-to-life preservation of biological materials by keeping them embedded in vitreous ice throughout the entire imaging process and the frozen-hydrated condition is very suitable to maintain fluorescent signals. In recent years, many new instruments and software which intended to optimize the workflow and to obtain better experimental results of CLEM have been presented or even commoditized. While, the specimen damage during transfer from FM to EM and the resolution of CLEM were still need to be improved.
Here we set up a High-vacuum Optical Platform to develop CLEM imaging technology (HOPE), which was designed to realize high-vacuum optical ( fluorescent) imaging for cryo-sample on EM cryo-holder (e.g. Gatan 626). A non-integrated high-vacuum cryo-optical stage, which adapted to the EM cryo holder, was fixed on epi-fluorescence microscope (or super-resolution microscope) to obtain fluorescent images. And then the EM cryo holder would be transferred to EM for collection of EM data. This protocol was aimed to minimize the specimen damage during transfer from FM to EM and it was versatile to expend to different types of light microscopy or electron microscopy. Our HOPE had already passed correlative imaging test, and the results showed that it was convenient and effective.
- Type
- Abstract
- Information
- Microscopy and Microanalysis , Volume 22 , Supplement S3: Proceedings of Microscopy & Microanalysis 2016 , July 2016 , pp. 248 - 249
- Copyright
- © Microscopy Society of America 2016