Hostname: page-component-78c5997874-94fs2 Total loading time: 0 Render date: 2024-11-20T04:18:25.818Z Has data issue: false hasContentIssue false

Microwave Processing for Sample Preparation to Evaluate Mitochondrial Ultrastructural Damage in Hemorrhagic Shock

Published online by Cambridge University Press:  15 November 2005

Gary D. Josephsen
Affiliation:
Section of Surgical Critical Care, Department of Surgery, University of Minnesota, Minneapolis, MN 55455, USA
Kelly A. Josephsen
Affiliation:
The Imaging Center, University of Minnesota, St. Paul, MN 55108, USA
Greg J. Beilman
Affiliation:
Section of Surgical Critical Care, Department of Surgery, University of Minnesota, Minneapolis, MN 55455, USA North Trauma Institute, North Memorial Health Care, Robbinsdale, MN 55422, USA
Jodie H. Taylor
Affiliation:
Section of Surgical Critical Care, Department of Surgery, University of Minnesota, Minneapolis, MN 55455, USA North Trauma Institute, North Memorial Health Care, Robbinsdale, MN 55422, USA Hennepin County Medical Center, Minneapolis, MN 55415, USA
Kristine E. Muiler
Affiliation:
Section of Surgical Critical Care, Department of Surgery, University of Minnesota, Minneapolis, MN 55455, USA
Get access

Abstract

This is a report of the adaptation of microwave processing in the preparation of liver biopsies for transmission electron microscopy (TEM) to examine ultrastructural damage of mitochondria in the setting of metabolic stress. Hemorrhagic shock was induced in pigs via 35% total blood volume bleed and a 90-min period of shock followed by resuscitation. Hepatic biopsies were collected before shock and after resuscitation. Following collection, biopsies were processed for TEM by a rapid method involving microwave irradiation (Giberson, 2001). Samples pre- and postshock of each of two animals were viewed and scored using the mitochondrial ultrastructure scoring system (Crouser et al., 2002), a system used to quantify the severity of ultrastructural damage during shock. Results showed evidence of increased ultrastructural damage in the postshock samples, which scored 4.00 and 3.42, versus their preshock controls, which scored 1.18 and 1.27. The results of this analysis were similar to those obtained in another model of shock (Crouser et al., 2002). However, the amount of time used to process the samples was significantly shortened with methods involving microwave irradiation.

Type
Biological Applications
Copyright
© 2005 Microscopy Society of America

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Cairns, C.B. (2001). Rude unhinging of the machinery of life: Metabolic approaches to hemorrhagic shock. Curr Opin Crit Care 6, 437443.Google Scholar
Cairns, C.B., Moore, F.A., Haenel, J.B., Gallea, B.L., Ortner, J.P., Rose, S.J., & Moore, E.E. (1997). Evidence for early supply independent mitochondrial dysfunction in patients developing multiple organ failure after trauma. J Trauma 42, 532536.Google Scholar
Crouser, E.D., Julian, M.W., Blaho, D.V., & Pfeiffer, D.R. (2002). Endotoxin-induced mitochondrial damage correlates with impaired respiratory activity. Crit Care Med 30, 276284.Google Scholar
Fink, M. (2001). Cytopathic hypoxia, mitochondrial dysfunction as a mechanism contributing to organ dysfunction in sepsis. Crit Care Clin 17, 219237.Google Scholar
Fox, C.H., Johnson, F.B., Whiting, J., & Roller, P.P. (1985). Formaldehyde fixation. J Histochem Cytochem 8, 845853.Google Scholar
Giberson, R.T. (2001). Vacuum-assisted microwave processing of animal tissues for electron microscopy. In Microwave Techniques and Protocols, Giberson, R.T. & Demaree, R.S. (Eds.), pp. 155164. Totowa, NJ: Humana Press.
Giberson, R.T. & Demaree, R.S., Jr. (1995). Microwave fixation: Understanding the variables to achieve rapid reproducible results. Microsc Res Tech 2, 246254.Google Scholar
Giberson, R.T. & Demaree, R.S. (1999). Microwave processing techniques for electron microscopy: A four hour protocol. In Methods in Molecular Biology, Hajibagheri, N. (Ed.), pp. 145158. Totowa, NJ: Humana Press.
Giberson, R.T., Demaree, R.S. Jr., & Nordhausen, R.W. (1997). Four-hour processing of clinical/diagnostic specimens for electron microscopy using microwave technique. J Vet Diagn Invest 9, 6167.Google Scholar
Kok, L.P. & Boon, M.E. (1997). Microwave methods for sample preparation in pathology. In Microwave-Enhanced Chemistry: Fundamentals, Sample Preparation, and Application, Kingston, H.M. & Haswell, S.J. (Eds.), pp. 644645. Washington, DC: American Chemical Society.
Moore, F.A., Haenel, J.B., & Moore, E.E. (1995). Early impaired oxygen consumption due to supply-independent mitochondrial dysfunction occurs in patients who develop Multiple Organ Failure. Surg Forum 46, 7476.Google Scholar
Russin, W.A. & Trivett, C.L. (2001). Vacuum-assisted microwave processing of animal tissues for electron microscopy. In Microwave Techniques and Protocols, Giberson, R.T. & Demaree, R.S. (Eds.), pp. 2535. Totowa, NJ: Humana Press.
Sanders, M.A. & Gartner, D.M. (2001). In vivo microwave-assisted labeling of allium and drosophila nuclei. In Microwave Techniques and Protocols. Giberson, R.T. & Demaree, R.S. (Eds.), pp. 155164. Totowa, NJ: Humana Press.
Taylor, J.H., Beilman, G.J., Conroy, M.J, Mulier, K.E., Myers, D., Gruessner, A., & Hammer, B.E. (2004). Tissue energetics as measured by nuclear magnetic resonance spectroscopy during hemorrhagic shock. Shock 21, 5864.Google Scholar
Trump, B.F., Berezesky, I.K., Laiho, K.U., Osornio, A.R., Mergner, W.J., & Smith, M.W. (1980). The role of calcium in cell injury. A review. Scan Electron Microsc 492, 437462.Google Scholar