Hostname: page-component-586b7cd67f-l7hp2 Total loading time: 0 Render date: 2024-11-22T09:22:18.337Z Has data issue: false hasContentIssue false

Measurement of Oxygen Diffusivity and Permeability in Polymers Using Fluorescence Microscopy

Published online by Cambridge University Press:  05 August 2010

Sanchari Chowdhury
Affiliation:
Department of Chemical & Biomedical Engineering, University of South Florida, Tampa, FL 33620-5350, USA
Venkat R. Bhethanabotla*
Affiliation:
Department of Chemical & Biomedical Engineering, University of South Florida, Tampa, FL 33620-5350, USA
Rajan Sen
Affiliation:
Department of Civil & Environmental Engineering, University of South Florida, Tampa, FL 33620-5350, USA
*
Corresponding author. E-mail: [email protected]
Get access

Abstract

A simple fluorescence microscopy technique is developed and presented to investigate heterogeneities in emission intensity and quenching responses of luminescence sensors and to measure diffusion and permeation coefficients of oxygen in polymers. Most luminescence oxygen sensors do not follow linearity of the Stern-Volmer (SV) equation due to heterogeneity of luminophore in the polymer matrix. To circumvent this limitation, inverted fluorescence microscopy is utilized in this work to investigate the SV response of the sensors at the micron scale. It was found that intensity is higher in regions where the luminophore is aggregated, but the response is poorer to oxygen concentration. In contrast, the nearly homogeneous regions exhibit linearity with high SV constants. In these diffusion experiments, oxygen concentration was measured by luminescence changes in regions with high SV constants and good linearity. Two diffusion experiments were performed—termed film-on-sensor and accumulation-in-volume techniques. A new Fick's law based quasi-steady-state diffusion model was developed and combined with the SV equation to obtain effective permeation coefficients for the accumulation-in-volume technique. Using these experimental techniques, oxygen diffusion properties in free-standing Teflon polymer films, cast silicon elastomers, and cast polydimethylsiloxane films containing different weight percentages of zeolite were determined with good precision.

Type
Fluorescence and Confocal Microscopies
Copyright
Copyright © Microscopy Society of America 2010

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Bedlek-Anslow, J.M., Hubner, J.P., Carroll, B.F. & Schanze, K.S. (2000). Micro-heterogeneous oxygen response in luminescence sensor films. Langmuir 16, 91379141.CrossRefGoogle Scholar
Bell, J.H., Schairer, E.T., Hand, L.A. & Mehta, R.D. (2001). Surface pressure measurements using lumienescent coatings. Ann Rev Fluid Mech 33, 155206.CrossRefGoogle Scholar
Bowman, R.D., Kneas, K.A., Demas, J.N. & Periasamy, A. (2003). Conventional, confocal and two-photon fluorescence microscopy investigations of polymer-supported oxygen sensors. J Microsc 211, 112120.CrossRefGoogle ScholarPubMed
Bowyer, W.J., Xu, W. & Demas, J.N. (2004). Determining oxygen diffusion coefficients in polymer films by lifetimes of luminescent complexes measured in the frequency domain. Anal Chem 76, 43744378.CrossRefGoogle ScholarPubMed
Carraway, E.R., Demas, J.N. & DeGraff, B.A. (1991a). Luminescence quenching mechanism for microheterogeneous systems. Anal Chem 63, 332336.CrossRefGoogle Scholar
Carraway, E.R., Demas, J.N. & DeGraff, B.A. (1991b). Photophysics and oxygen quenching of transition-metal complexes on fumed silica. Langmuir 7, 29912998.CrossRefGoogle Scholar
Carraway, E.R., Demas, J.N., DeGraff, B.A. & Bacon, J.R. (1991c). Photophysics and photochemistry of oxygen sensors based on luminescent transition-metal complexes. Anal Chem 63, 337342.CrossRefGoogle Scholar
Cox, M.E. (1986). Oxygen diffusion in poly(dimethyl siloxane) using fluorescence quenching. I. Measurement technique and analysis. J Polymer Sci A 24, 621636.Google Scholar
Crank, J. (1975). The Mathematics of Diffusion. New York: Oxford University Press.Google Scholar
Demas, J.N., Deora, B.A. & Xut, W. (1995). Modeling of luminescence quenching-based sensors: Comparison of multisite and nonlinear gas solubility models. Anal Chem 67, 13771380.CrossRefGoogle Scholar
Draxler, S. & Lippitsch, M.E. (1996). Lifetime-based sensing: Influence of the microenvironment. Anal Chem 68, 753757.CrossRefGoogle ScholarPubMed
Draxler, S., Lippitsch, M.E., Klimant, I., Kraus, M. & Wolfbeis, O.S. (1995). Effects of polymer matrices on the time-resolved luminescence of a ruthenium complex quenched by oxygen. J Phys Chem 99, 31623167.CrossRefGoogle Scholar
Fischkoff, S. & Vanderkooi, J.M. (1975). Oxygen diffusion in biological and artificial membranes determined by the fluorochrome pyrene. J Gen Physiol 65, 663676.CrossRefGoogle ScholarPubMed
Jayarajah, C.N. (1998). Luminescence quenching studies of oxygen diffusion in highly permeable media. MSc Thesis. Toronto, Canada: Department of Chemistry, University of Toronto.Google Scholar
Jayarajah, C.N., Yekta, A., Manners, I. & Winnik, M.A. (2000). Oxygen diffusion and permeability in alkylaminothionylphosphazene films intended for phosphorescence barometry applications. Macromolecules 33, 56935701.CrossRefGoogle Scholar
Jia, M., Peinemann, K.-V. & Behling, R.-D. (1991). Molecular sieving effect of zeolite-filled silicone rubber membranes in gas permeation. J Membr Sci 57, 289292.CrossRefGoogle Scholar
Kneas, K.A., Demas, J.N., DeGraff, B.A. & Periasamy, A. (2000). Fluorescence microscopy study of heterogeneity in polymer-supported luminescence-based oxygen sensors. Microsc Microanal 6, 551561.CrossRefGoogle ScholarPubMed
Kneas, K.A., Demas, J.N., Nguyen, B., Lockhart, A., Xu, W. & DeGraff, B.A. (2002). Method for measuring oxygen diffusion coefficients of polymer films by luminescence quenching. Anal Chem 74, 11111118.CrossRefGoogle ScholarPubMed
Koros, W.J., Wang, J. & Felder, R.M. (1981). Oxygen permeation through FEP teflon and kapton polyimide. J Appl Polym Sci 26, 28052809.CrossRefGoogle Scholar
Lee, S.-K. & Okura, I. (1997). Photostable optical oxygen sensing material: Platinum tetrakis(pentafluorophenyl)porphyrin Immobilized in polystyrene. Anal Comm 34, 185188.CrossRefGoogle Scholar
Li, X.-M. & Wong, K.-Y. (1992). Luminescent platinum complex in solid films for optical sensing of oxygen. Anal Chim Acta 262(1), 2732.CrossRefGoogle Scholar
Lu, X., Manners, I. & Winnik, M.A. (2001). Polymer/silica composite films as luminescent oxygen sensors. Macromolecules 34, 19171927.CrossRefGoogle Scholar
Lu, X. & Winnik, M.A. (2001). Luminescence quenching in polymer/filler nanocomposite films used in oxygen sensors. Chem Mater 13, 34493463.CrossRefGoogle Scholar
Paul, D.R. & Dibenedetto, A.T. (1965). Diffusion in amorphous polymers. J Polym Sci C 10, 1744.CrossRefGoogle Scholar
Paul, D.R. & Kemp, D.R. (1973). The diffusion time lag in polymer membranes containing adsorptive fillers. J Polym Sci Symp 41, 7993.CrossRefGoogle Scholar
Pekcan, O. & Uğur, S. (1999). Oxygen diffusion into latex films annealed at various temperatures: A fluorescence study. J Colloid Interface Sci 217, 154159.CrossRefGoogle ScholarPubMed
Rharbi, Y., Yekta, A. & Winnik, M.A. (1999). A method for measuring oxygen diffusion and oxygen permeation in polymer films based on fluorescence quenching. Anal Chem 71, 50455053.CrossRefGoogle Scholar
Ruffolo, R., Evans, C.E.B., Liu, X.-H., Ni, Y., Pang, Z., Park, P., McWilliams, A.R., Gu, X., Lu, X., Yekta, A., Winnik, M.A. & Manners, I. (2000). Phosphorescent oxygen sensors utilizing sulfur-nitrogen-phosphorus polymer matrixes: Synthesis, characterization, and evaluation of Poly(thionylphosphazene)-b-Poly(tetrahydrofuran) block copolymers. Anal Chem 72, 18941904.CrossRefGoogle Scholar
Sacksteder, L.A., Demas, J.N. & DeGraff, B.A. (1993). Design of oxygen sensors based on quenching of luminescent metal complexes: Effect of ligand size on heterogeneity. Anal Chem 65, 34803483.CrossRefGoogle Scholar
Schappacher, G. & Hartmann, P. (2003). Partial analytical solution of a model used for measuring oxygen diffusion coefficients of polymer films by luminescence quenching. Anal Chem 75, 43194324.CrossRefGoogle Scholar
Shiku, H., Saito, T., Wu, C., Yasukawa, T., Yokoo, M., Abe, H., Matsue, T. & Yamada, H. (2006). Oxygen permeability of surface-modified poly(dimethylsiloxane) characterized by scanning electrochemical microscopy. Chem Lett 35(2), 234255.CrossRefGoogle Scholar
Stern, O. & Volmer, M. (1919). Über die Abklingzeit der Fluoreszenz. M Phys Z 20, 183188.Google Scholar
Süer, M.G., Bac, N. & Yilmaz, L. (1994). Gas permeation characteristics of polymer-zeolite mixed matrix membranes. J Membr Sci 91, 7786.CrossRefGoogle Scholar
Yekta, A., Masoumi, Z. & Winnik, M.A. (1995). Luminescence measurements of oxygen permeation and oxygen diffusion in thin polymer films. Can J Chem 73, 20212029.CrossRefGoogle Scholar