Image Periodicities Introduced by Three-Fold Astigmatism in HRTEM Images of α-Al2O3 and Related Materials

Published online by Cambridge University Press:  02 July 2020

D.L. Medlin
Affiliation:
Materials and Engineering Sciences Center, Sandia National Laboratories, Livermore, CA94550
J.E. Smugeresky
Affiliation:
Materials and Engineering Sciences Center, Sandia National Laboratories, Livermore, CA94550
D. Cohen
Affiliation:
Department of Chemical Eng. and Mat. Science, University of Minnesota, Minneapolis, MN55455
Get access

Extract

HRTEM images of α-Al2O3 oriented along [1100] often exhibit a modulation of the basal fringe intensity with a period that corresponds to twice the basal plane spacing. In the example shown in figure 1, note the strong basal fringe contrast in the A12O3 with a period of 4.33 Å. HRTEM image simulations for ideal imaging conditions fail to reproduce this doubling of the lattice fringe period. Instead, simulated images predict that the (0006) fringes (d0006=2.17 Å) should be of equal intensity (e.g., see Figure 3a). Incorrect beam and/or crystal tilt can strongly affect HRTEM image contrast. In particular, anomalous periodicities can arise under beam and crystal tilt conditions for which normally kinematically and dynamically forbidden diffracted beams contribute to the image. More recently, the importance of 3-fold astigmatism on HRTEM imaging has been recognized. As with beam tilt, this lens aberration produces asymmetrical phase shifts in the diffracted beams.

Type
Microscopy of Ceramics and Minerals
Copyright
Copyright © Microscopy Society of America

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

References:

1.Smith, D.J., Saxton, W.O., O'Keefe, M.A., Wood, G.J., Stobbs, W.M., Ultramicroscopy 11 (1983) 263282.CrossRefGoogle Scholar
2.O'Keefe, M.A. and Radmilovic, V., 51st Ann. Proc. MSA (1993) 980981.Google Scholar
3.Smith, D.J., Bursill, L.A., Wood, G.J., Ultramicroscopy 16 (1985) 1932.CrossRefGoogle Scholar
4.Krivanek, O.L., Ultramicroscopy 55 (1994) 419433.CrossRefGoogle Scholar
5.Saxton, W.O., Ultramicroscopy 58 (1995) 239243.CrossRefGoogle Scholar
6.Krivanek, O.L. and Stadelmann, P.A., Ultramicroscopy 60 (1995) 103113.CrossRefGoogle Scholar
7.Merkle, K.L., Csencsits, R., Rynes, K.L., Withrow, J.P., and Stadelmann, P.A., Journal of Microscopy 189 (3) (1998).Google Scholar
8.Stadelmann, P., Ultramicroscopy 21 (1987) 131.CrossRefGoogle Scholar
9. This work is supported at Sandia National Laboratories by the U.S. Department of Energy under contract DE-AC04-94AL85000 and in part by OBES-DMS. The authors thank Prof. P. A. Stadelmann for providing us with the updated version of EMS incorporating 3-fold astigmatism.Google Scholar