Hostname: page-component-586b7cd67f-rcrh6 Total loading time: 0 Render date: 2024-11-20T06:26:22.629Z Has data issue: false hasContentIssue false

How Multiphoton Excitation can Illuminate Biophysics

Published online by Cambridge University Press:  02 July 2020

W. W. Webb*
Affiliation:
School of Applied and Engineering Physics, Cornell University, Ithaca, NY14853-2501
Get access

Extract

Multiphoton molecular excitation by the strongly focused femtosecond pulses of infrared light generated as an 80 MHZ pulse train by a mode locked laser provides intrinsic submicron three dimensional spatial resolution of fluorescence excitation and photochemistry for laser scanning fluorescence microscopy. Because two-photon excitation requires simultaneous (∼10-16 seconds), absorption of two-photons focused laser intensities of about 1022 photons/cm2s are required. Since the rate of absorption is proportional to the square of the intensity, excitation is limited to the focal volume and is negligible elsewhere along the double cone of the focused illumination. Therefore, out of focus photodamage and fluorescence are generally negligible and laser scanning fluorescence microscopy with multiphoton excitation is intrinsically three dimensionally resolved with no out of focus background. Since the appropriate wave lengths are infrared for multiphoton excitation of ultraviolet or visible absorbing molecules, out of focus photodamage is eliminated. This allows imaging of useful ultraviolet absorbing indicators, vital DNA stains and autofluorescence in living cells with minimal, but not necessarily negligible, photodamage.

Type
Biological Applications of Multi-photon Excitation Fluorescence Imaging
Copyright
Copyright © Microscopy Society of America 1997

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Winfried, Denket al., “Two-Photon Laser Scanning Fluorescence Microscopy,Science 248 (1990)7376.Google Scholar
2.Winfried, Denket al., “ Two-Photon Molecular Excitation in Laser Scanning Microscopy”, Handbook of Biological Confocal Microscopy. invited review chapter, ed. by Pawley, J., (1995) 445458.Google Scholar
3.Williams, Rebecca M.et al., “Two photon molecular excitation provides intrinsic three dimensional resolution for laser-based microscopy and microphotochemistry”, FASEB Journal, 8, (1994)804813.10.1096/fasebj.8.11.8070629CrossRefGoogle ScholarPubMed
4.Maiti, S.et al., “Measuring Serotonin Distribution in Live Cells with Three-Photon Excitation,Science 275: (1997)530.10.1126/science.275.5299.530CrossRefGoogle Scholar