Hostname: page-component-78c5997874-xbtfd Total loading time: 0 Render date: 2024-11-17T18:19:53.542Z Has data issue: false hasContentIssue false

High-Resolution X-ray Spectroscopy Close to Room Temperature

Published online by Cambridge University Press:  28 July 2005

L. Strüder
Affiliation:
MPI für Extraterrestrische Physik, Halbleiterlabor, Paul-Gerhardt-Allee 42, D-81245 Munich, Germany
N. Meidinger
Affiliation:
MPI für Extraterrestrische Physik, Halbleiterlabor, Paul-Gerhardt-Allee 42, D-81245 Munich, Germany
D. Stotter
Affiliation:
MPI für Extraterrestrische Physik, Halbleiterlabor, Paul-Gerhardt-Allee 42, D-81245 Munich, Germany
J. Kemmer
Affiliation:
KETEK GmbH, Am Isarbach 30, D-85764 Oberschleissheim, Germany
P. Lechner
Affiliation:
KETEK GmbH, Am Isarbach 30, D-85764 Oberschleissheim, Germany
P. Leutenegger
Affiliation:
KETEK GmbH, Am Isarbach 30, D-85764 Oberschleissheim, Germany
H. Soltau
Affiliation:
KETEK GmbH, Am Isarbach 30, D-85764 Oberschleissheim, Germany
F. Eggert
Affiliation:
RONTEC GmbH, Rudower Chaussee 6, D-12489 Berlin, Germany
M. Rohde
Affiliation:
RONTEC GmbH, Rudower Chaussee 6, D-12489 Berlin, Germany
T. Schulein
Affiliation:
RONTEC GmbH, Rudower Chaussee 6, D-12489 Berlin, Germany
Get access

Abstract

Originally designed as position-sensitive detectors for particle tracking, silicon drift detectors (SDDs) are now used for high-count rate X-ray spectroscopy, operating close to room temperature. Their low-capacitance read-node concept places them among the fastest high-resolution detector systems. They have been used in a new spectrum of experiments in the wide field of X-ray spectroscopy: fluorescent analysis, diffrac-tometry, materials analysis, and synchrotron experiments such as X-ray holography and element imaging in scanning electron microscopes. The fact that the detector system can be used at room temperature with good spectroscopic performance and at −10°C with excellent energy resolution, avoiding liquid nitrogen for cooling and high-quality vacuum, guarantees a large variety of new applications, independent of the laboratory environment. A brief description of the device principles is followed by basics on low noise amplification. The performance results of a complete detector system are presented as well as some dedicated applications already realized, including use in a surface mapping instrument and use of a “mini-spectrometer” for the analysis of works of art. Fully depleted pn-charge-coupled devices (pn-CCDs) have been fabricated for the European X-ray Multi-Mirror mission (XMM) and the German X-ray satellite ABRIXAS, enabling high-speed, low-noise, position-resolving X-ray spectroscopy. The detector was designed and fabricated with a homogeneously sensitive area of 36 cm2. At −70°C it has a noise of 4 e- rms, with a readout time of the total focal plane array of 4 msec. The maximum count rate for single photon counting was 105 cps under flat field conditions. In the integration mode, more than 109 cps can be detected at 6 keV. Its position resolution is on the order of 100 μm. The quantum efficiency is higher than 90%, ranging from carbon K X-rays (277 eV) up to 10 keV.

Type
1998 TOPICAL SYMPOSIUM OF THE MICROBEAM ANALYSIS SOCIETY
Copyright
© 2005 Microscopy Society of America

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)