Hostname: page-component-78c5997874-m6dg7 Total loading time: 0 Render date: 2024-11-17T19:18:26.330Z Has data issue: false hasContentIssue false

Geometric Alignment Of Cone-Beam Helical-Trajectory Micro-Tomography Data Using a PI-Line Difference Metric

Published online by Cambridge University Press:  10 August 2018

Olaf Delgado-Friedrichs
Affiliation:
Dept. of Applied Mathematics, Research School of Physics and Engineering, The Australian National University, Canberra, ACT 2601, Australia. CTLab: National Laboratory for Micro Computed-Tomography, Advanced Imaging Precinct, The Australian National University, Canberra, ACT 2601, Australia.
Andrew M. Kingston*
Affiliation:
Dept. of Applied Mathematics, Research School of Physics and Engineering, The Australian National University, Canberra, ACT 2601, Australia. CTLab: National Laboratory for Micro Computed-Tomography, Advanced Imaging Precinct, The Australian National University, Canberra, ACT 2601, Australia.
Shane J. Latham
Affiliation:
Dept. of Applied Mathematics, Research School of Physics and Engineering, The Australian National University, Canberra, ACT 2601, Australia. CTLab: National Laboratory for Micro Computed-Tomography, Advanced Imaging Precinct, The Australian National University, Canberra, ACT 2601, Australia.
Glenn R. Myers
Affiliation:
Dept. of Applied Mathematics, Research School of Physics and Engineering, The Australian National University, Canberra, ACT 2601, Australia. CTLab: National Laboratory for Micro Computed-Tomography, Advanced Imaging Precinct, The Australian National University, Canberra, ACT 2601, Australia.
Adrian P. Sheppard
Affiliation:
Dept. of Applied Mathematics, Research School of Physics and Engineering, The Australian National University, Canberra, ACT 2601, Australia. CTLab: National Laboratory for Micro Computed-Tomography, Advanced Imaging Precinct, The Australian National University, Canberra, ACT 2601, Australia.
*
*Corresponding author, [email protected]

Abstract

Image of the first page of this content. For PDF version, please use the ‘Save PDF’ preceeding this image.'
Type
Abstract
Copyright
© Microscopy Society of America 2018 

References

[1] Kingston, A., et al, Medical Physics 38 2011) p. 4934.CrossRefGoogle Scholar
[2] Kingston, A., et al, Proceedings ICTMS 2013) p. 101.Google Scholar
[3] Varslot, T., et al, SPIE Optical Engineering + Applications 2012) p. 850614.Google Scholar
[4] Kingston, A. M., et al, SPIE Optics and Photonics 2016) p. 996710038.Google Scholar
[5] The authors acknowledge the financial support of the Australian Research Council and FEI-Thermo Fisher Scientific through Linkage Project LP150101040, and the use of super-computer time provided by Australia's National Computational Infrastructure (NCI).Google Scholar