Hostname: page-component-586b7cd67f-rdxmf Total loading time: 0 Render date: 2024-11-20T10:38:38.036Z Has data issue: false hasContentIssue false

Experiments on Foucault Imaging of Superconducting Fluxons

Published online by Cambridge University Press:  02 July 2020

T. Yoshida
Affiliation:
Advanced Research Laboratory, Hitachi Ltd., Hatoyama,Saitama350-03, Japan.
J. Endo
Affiliation:
Advanced Research Laboratory, Hitachi Ltd., Hatoyama,Saitama350-03, Japan.
K. Harada
Affiliation:
Advanced Research Laboratory, Hitachi Ltd., Hatoyama,Saitama350-03, Japan.
H. Kasai
Affiliation:
Advanced Research Laboratory, Hitachi Ltd., Hatoyama,Saitama350-03, Japan.
T. Matsuda
Affiliation:
Advanced Research Laboratory, Hitachi Ltd., Hatoyama,Saitama350-03, Japan.
M. Beleggia
Affiliation:
Department of Physics and Istituto Nazionale di Fisica per la Materia,viale B. Pichat 6/2, 40127, Bologna, Italy.
G. Pozzi
Affiliation:
Department of Physics and Istituto Nazionale di Fisica per la Materia,viale B. Pichat 6/2, 40127, Bologna, Italy.
A. Tonomura
Affiliation:
Advanced Research Laboratory, Hitachi Ltd., Hatoyama,Saitama350-03, Japan.
Get access

Extract

The out-of-focus method has been successfully employed in the dynamical observation of superconducting fluxons. However, owing to the large defocus distance needed to image fluxons with enough contrast it turns out that their correlation with structural defects, better imaged at focus, is troublesome. Among the standard methods of Lorentz microscopy the Foucault technique is a good candidate for removing this drawback, since it generates phase contrast in the focused image by masking part of the transmitted beam by means of an aperture.

Therefore, simulations have been carried out both for one-dimensional fluxon models and more realistic two dimensional ones, with the result that enough contrast can be generated in the focused image in order to detect them. However, although these theoretical results suggest the feasibility of Foucault experiments, filling the gap between theory and practice is not an easy task, especially when considering the small angular deflections involved, of the order of 10−5 rad.

Type
Recent Developments in Microscopy for Studying Electronic and Magnetic Materials
Copyright
Copyright © Microscopy Society of America 1997

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1Harada, K.et al., Jpn. J. Appl. Phys. 33 (1994) 2534.10.1143/JJAP.33.2534CrossRefGoogle Scholar
2Harada, K.et al., Science 274 (1966) 1167.10.1126/science.274.5290.1167CrossRefGoogle Scholar
3Bonevich, J.E.et al., Phys. Rev. B 49 (1994) 6800.10.1103/PhysRevB.49.6800CrossRefGoogle Scholar
4Chapman, J.N., J. Phys. D17 (1984) 623.Google Scholar
5Pozzi, G.et al., Microsc. Microanal. Microstruct. 6 (1995) 559.10.1051/mmm:1995148CrossRefGoogle Scholar
6Beleggia, M.et al., Proc. Eurem96, Dublin (1996.)Google Scholar
7Beleggia, M.et al., These Proceedings.Google Scholar
8Huebener, R.P.,Magnetic Flux Structures in Superconductors, Springer,Berlin (1979).10.1007/978-3-662-02305-1CrossRefGoogle Scholar