Hostname: page-component-586b7cd67f-t7fkt Total loading time: 0 Render date: 2024-11-25T00:32:55.175Z Has data issue: false hasContentIssue false

Use of viral DNA surrogate markers to study routes of transmission of healthcare-associated pathogens

Published online by Cambridge University Press:  30 September 2020

Manish Thakur
Affiliation:
Research Service, Louis Stokes Veterans’ Affairs Medical Center, Cleveland, Ohio
Heba Alhmidi
Affiliation:
Geriatric Research, Education and Clinical Center, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio
Jennifer L. Cadnum
Affiliation:
Research Service, Louis Stokes Veterans’ Affairs Medical Center, Cleveland, Ohio
Annette L. Jencson
Affiliation:
Research Service, Louis Stokes Veterans’ Affairs Medical Center, Cleveland, Ohio
Jessica Bingham
Affiliation:
Nursing Service, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio
Brigid M. Wilson
Affiliation:
Geriatric Research, Education and Clinical Center, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio
Curtis J. Donskey*
Affiliation:
Geriatric Research, Education and Clinical Center, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio Case Western Reserve University School of Medicine, Cleveland, Ohio
*
Author for correspondence: Curtis J. Donskey, E-mail: [email protected]

Abstract

Background:

The hands of healthcare personnel are the most important source for transmission of healthcare-associated pathogens. The role of contaminated fomites such as portable equipment, stethoscopes, and clothing of personnel in pathogen transmission is unclear.

Objective:

To study routes of transmission of cauliflower mosaic virus DNA markers from 31 source patients and from environmental surfaces in their rooms.

Design:

A 3-month observational cohort study.

Setting:

A Veterans’ Affairs hospital.

Methods:

After providing care for source patients, healthcare personnel were observed during interactions with subsequent patients. Putative routes of transmission were identified based on recovery of DNA markers from sites of contact with the patient or environment. To assess plausibility of fomite-mediated transmission, we assessed the frequency of transfer of methicillin-resistant Staphylococcus aureus (MRSA) from the skin of 25 colonized patients via gloved hands versus fomites.

Results:

Of 145 interactions involving contact with patients and/or the environment, 41 (28.3%) resulted in transfer of 1 or both DNA markers to the patient and/or the environment. The DNA marker applied to patients’ skin and clothing was transferred most frequently by stethoscopes, hands, and portable equipment, whereas the marker applied to environmental surfaces was transferred only by hands and clothing. The percentages of MRSA transfer from the skin of colonized patients via gloved hands, stethoscope diaphragms, and clothing were 52%, 40%, and 48%, respectively.

Conclusions:

Fomites such as stethoscopes, clothing, and portable equipment may be underappreciated sources of pathogen transmission. Simple interventions such as decontamination of fomites between patients could reduce the risk for transmission.

Type
Original Article
Copyright
© 2020 by The Society for Healthcare Epidemiology of America. All rights reserved.

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Donskey, CJ. Does improving surface cleaning and disinfection reduce health care-associated infections? Am J Infect Control 2013;41:S12S19.CrossRefGoogle ScholarPubMed
Anderson, DJ, Addison, R, Lokhnygina, Y, et al. The Antimicrobial Scrub Contamination and Transmission (ASCOT) trial: a three-arm, blinded, randomized controlled trial with crossover design to determine the efficacy of antimicrobial-impregnated scrubs in preventing healthcare provider contamination. Infect Control Hosp Epidemiol 2017;38:11471154.CrossRefGoogle ScholarPubMed
John, AR, Alhmidi, H, Gonzalez-Orta, MI, Cadnum, JL, Donskey, CJ. A randomized trial to determine whether wearing short-sleeved white coats reduces risk of pathogen transmission. Infect Control Hosp Epidemiol 2018;39:233234.CrossRefGoogle ScholarPubMed
Donskey, CJ. Beyond high-touch surfaces: portable equipment and floors as potential sources of transmission of health care-associated pathogens. Am J Infect Control 2019;47S:A90A95.CrossRefGoogle ScholarPubMed
Kanamori, H, Rutala, WA, Weber, DJ. The role of patient care items as a fomite in healthcare-associated outbreaks and infection prevention. Clin Infect Dis 2017;65:14121419.CrossRefGoogle ScholarPubMed
Eyre, DW, Sheppard, AE, Madder, H, et al. A Candida auris outbreak and its control in an intensive care setting. N Engl J Med 2018;379:13221331.CrossRefGoogle Scholar
Jernigan, JA, Siegman-Igra, Y, Guerrant, RC, Farr, BM. A randomized crossover study of disposable thermometers for prevention of C. difficile and other nosocomial infections. Infect Control Hosp Epidemiol 1998;19:494499.CrossRefGoogle Scholar
Vajravelu, RK, Vajravelu, RK, Guerrero, DM, Jury, LA, Donskey, CJ. Evaluation of stethoscopes as vectors of Clostridium difficile and methicillin-resistant Staphylococcus aureus . Infect Control Hosp Epidemiol 2012;33:9698.CrossRefGoogle ScholarPubMed
Longtin, Y, Schneider, A, Tschopp, C, et al. Contamination of stethoscopes and physicians’ hands after a physical examination. Mayo Clin Proc 2014;89:291299.CrossRefGoogle ScholarPubMed
Oelberg, DG, Joyner, SE, Jiang, X, Laborde, D, Islam, MP, Pickering, LK. Detection of pathogen transmission in neonatal nurseries using DNA markers as surrogate indicators. Pediatrics 2000;105:311315.CrossRefGoogle ScholarPubMed
John, A, Alhmidi, H, Cadnum, JL, Jencson, AL, Donskey, CJ. Contaminated portable equipment is a potential vector for dissemination of pathogens in the intensive care unit. Infect Control Hosp Epidemiol 2017;38:12471249.CrossRefGoogle ScholarPubMed
John, AR, Alhmidi, H, Cadnum, JL, Jencson, AL, Gestrich, S, Donskey, CJ. Evaluation of the potential for electronic thermometers to contribute to spread of healthcare-associated pathogens. Am J Infect Control 2018;46:708710.CrossRefGoogle ScholarPubMed
Alhmidi, H, Cadnum, JL, Jencson, AL, Gweder, AA, Donskey, CJ. Sharing is not always a good thing: Use of a DNA marker to investigate the potential for ward-to-ward dissemination of healthcare-associated pathogens. Infect Control Hosp Epidemiol 2019;40:214216.CrossRefGoogle Scholar
Alhmidi, H, Koganti, S, Cadnum, JL, Jencson, AL, John, A, Donskey, CJ. Dissemination of a nonpathogenic viral DNA surrogate marker from high-touch surfaces in rooms of long-term care facility residents. Am J Infect Control 2017;45:11651167.CrossRefGoogle ScholarPubMed
Alhmidi, H, John, A, Mana, TC, Koganti, S, Cadnum, JL, Shelton, MB, Donskey, CJ. Evaluation of viral surrogate markers for study of pathogen dissemination during simulations of patient care. Open Forum Infect Dis 2017;4:ofx128.CrossRefGoogle Scholar
Kanwar, A, Mana, TSC, Cadnum, JL, Alhmidi, H, Koganti, S, Donskey, CJ. How well does transfer of bacterial pathogens by culture swabs correlate with transfer by hands? Am J Infect Control 2017;45:923925.CrossRefGoogle ScholarPubMed
Alhmidi, H, Cadnum, JL, Koganti, S, et al. Shedding of methicillin-resistant Staphylococcus aureus by colonized patients during procedures and patient care activities. Infect Control Hosp Epidemiol 2019;40:328332.CrossRefGoogle ScholarPubMed
Kanwar, A, Thakur, M, Wazzan, M, Satyavada, S, Cadnum, JL, Jencson, AL, Donskey, CJ. Clothing and shoes of personnel as potential vectors for transfer of healthcare-associated pathogens to the community. Am J Infect Control 2019;47:577579.CrossRefGoogle ScholarPubMed