Hostname: page-component-78c5997874-m6dg7 Total loading time: 0 Render date: 2024-11-18T18:56:07.882Z Has data issue: false hasContentIssue false

SYSTOLIC CORONARY FLOW IMPEDIMENT IN THE DOG: ROLE OF VENTRICULAR PRESSURE AND CONTRACTILITY

Published online by Cambridge University Press:  03 January 2001

PASQUALE PAGLIARO
Affiliation:
Division of Biomedical Sciences, King's College London, London WC2R 2LS, UK
DONATELLA GATTULLO
Affiliation:
Dipartimento di Scienze Cliniche e Biologiche dell'Università di Torino, 10043 Orbassano, Italy
RONALD J. LINDEN
Affiliation:
Dipartimento di Scienze Cliniche e Biologiche dell'Università di Torino, 10043 Orbassano, Italy
GIANNI LOSANO
Affiliation:
Dipartimento di Scienze Cliniche e Biologiche dell'Università di Torino, 10043 Orbassano, Italy
NICO WESTERHOF
Affiliation:
Laboratory for Physiology, Institute for Cardiovascular Research, ICaR-VU, Free University, Amsterdam, The Netherlands
Get access

Abstract

The present study was planned to investigate the effect of left ventricular pressure and inotropic state on coronary arterial inflow in systole in the anaesthetized dog. A wide range of left ventricular systolic pressures, including the physiological range, were studied. Experiments were done under conditions of maximal vasodilatation and low perfusion pressure in order to avoid vascular autoregulative interference and to keep the microvascular pressure within the normal range. In five anaesthetized dogs, perfused with extracorporeal circulation system, ventricular volume was changed from 20 to 50 ml in steps of 10 ml by filling an intraventricular latex balloon, and the related changes in left ventricular pressure and coronary flow were measured. The volume was then extended to 70 ml to obtain an overstretch which induced a transient decrease in cardiac contractility. During the period of low cardiac contractility the volume was brought back to 20 ml in steps of 10 ml. Systolic ventricular pressure changed with volume but was lower during the period of low contractility. For systolic pressures below 100 mmHg there was no significant relationship between pressure and coronary systolic flow, but the relationship shifted to higher flows during low contractility. For systolic pressures above 100 mmHg systolic coronary flow decreased significantly when systolic pressure increased. In this case the slopes of the relationships were not significantly different before and after the reduction in contractility. These findings suggest that for systolic pressures less than 100 mmHg (i.e. below the physiological range) the shielding effect of the contracting ventricle prevents the ventricular pressure from being transmitted in the myocardial wall. When systolic pressure exceeds 100 mmHg the shielding effect is overcome and the amplitude of the systolic flow reduction varies with ventricular pressure.

Type
Research Article
Copyright
© The Physiological Society 1998

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)