Hostname: page-component-586b7cd67f-t7czq Total loading time: 0 Render date: 2024-11-30T07:27:36.500Z Has data issue: false hasContentIssue false

Technical Variables Related to the Application of Electroconvulsive Therapy in the “Hospital 12 de Octubre”, Madrid

Published online by Cambridge University Press:  16 April 2020

D. Ballesteros Sanz
Affiliation:
Psiquiatría, Hospital 12 Octubre, Madrid, Spain
E.J. Verdura Vizcaíno
Affiliation:
Psiquiatría, Hospital 12 Octubre, Madrid, Spain
M. Marín Mayor
Affiliation:
Psiquiatría, Hospital 12 Octubre, Madrid, Spain
M.Á. Hurtado Calvo
Affiliation:
Psiquiatría, Hospital 12 Octubre, Madrid, Spain
D. del Peso Martínez
Affiliation:
Psiquiatría, Hospital 12 Octubre, Madrid, Spain
F.J. Sanz-Fuentenebro
Affiliation:
Psiquiatría, Hospital 12 Octubre, Madrid, Spain

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.
Background

Electroconvulsive Therapy (ECT) is a safe and effective technique widely used in our area. Scientific literature related to the application of this technique is continuously developing, specifically with regard to the placement of the electrodes, the amplitude of the stimulus pulse administered, the initial charge used, and the anesthetic agent involved.

Aims

The primary aim of this study was to analyze technical variables associated with the use of ECT in our hospital, and compare them to the guidelines of the protocol developed in our hospital and international standards.

Methods

We performed a review of Clinical Histories of the patients that were treated with ECT in the “Hospital 12 de Octubre” (Madrid, Spain), in the period comprised between January 1st, 2008 and December 31st, 2009. We collected data related to the application of the technique, socio-demographic variables and clinical profiles. We used descriptive statistics to analyze our data.

Results

During this period, 602 ECT sessions were applied. Placement of the electrodes was unilateral in 58% of subjects with Affective Disorders and 8% of subjects with Schizophrenia. The amplitude of the stimulus pulse was 1 ms. Mean charge administered in the initial and final session was 236.85 mC and 357.16 mC, respectively. Etomidate was used as anesthetic in 68% of cases.

Conclusions

ECT technical variables applied in our hospital are adjusted to guidelines of our area and international recommendations. Longitudinal studies are warranted in order to objectively assess techinical variables associated to ECT.