Hostname: page-component-cd9895bd7-q99xh Total loading time: 0 Render date: 2024-12-23T08:26:23.539Z Has data issue: false hasContentIssue false

Usefulness of intracardiac echocardiography for the diagnosis of infective endocarditis following percutaneous pulmonary valve replacement

Published online by Cambridge University Press:  21 March 2017

Sara Bouajila
Affiliation:
Cardiology Department, CHU Clermont-Ferrand, University of Auvergne, Clermont-Ferrand, France
Aurélie Chalard
Affiliation:
Cardiology Department, CHU Clermont-Ferrand, University of Auvergne, Clermont-Ferrand, France
Claire Dauphin*
Affiliation:
Cardiology Department, CHU Clermont-Ferrand, University of Auvergne, Clermont-Ferrand, France
*
Correspondence to: C. Dauphin, MD, Cardiology Department, CHU Clermont-Ferrand, University of Auvergne, 58 rue Montalembert, 63003 Clermont-Ferrand, France. Tel: +33 473 751 412; Fax: +33 473 751 454; E-mail: [email protected]

Abstract

Infective endocarditis is a serious complication occurring after percutaneous pulmonary valve replacement with a Melody valve; it is of uncertain incidence, and presents a challenging diagnosis. Vegetations may be difficult to visualise with transthoracic and transoesophageal echocardiography. We report the role of intracardiac echocardiography in this condition by confirming the prosthesis involvement.

Type
Brief Report
Copyright
© Cambridge University Press 2017 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Li, JS, Sexton, DJ, Mick, N, et al. Proposed modifications to the Duke criteria for the diagnosis of infective endocarditis. Clin Infect Dis 2000; 30: 633638.Google Scholar
2. Patel, M, Malekzadeh-Milani, S, Ladouceur, M, Iserin, L, Boudjemline, Y. Percutaneous pulmonary valve endocarditis: incidence, prevention and management. Arch Cardiovasc Dis 2014; 107: 615624.Google Scholar
3. Buber, J, Bergersen, L, Lock, JE, et al. Bloodstream infections occurring in patients with percutaneously implanted bioprosthetic pulmonary valve: a single-center experience. Circ Cardiovasc Interv 2013; 6: 301310.CrossRefGoogle ScholarPubMed
4. Awad, SM, Masood, SA, Gonzalez, I, et al. The use of intracardiac echocardiography during percutaneous pulmonary valve replacement. Pediatr Cardiol 2015; 36: 7683.Google Scholar
5. Narducci, ML, Pelargonio, G, Russo, E, et al. Usefulness of intracardiac echocardiography for the diagnosis of cardiovascular implantable electronic device-related endocarditis. J Am Coll Cardiol 2013; 61: 13981405.CrossRefGoogle ScholarPubMed
6. Cheung, G, Vejlstrup, N, Ihlemann, N, et al. Infective endocarditis following percutaneous pulmonary valve replacement: diagnostic challenges and application of intra-cardiac echocardiography. Int J Cardiol 2013; 169: 425429.CrossRefGoogle ScholarPubMed
Supplementary material: File

Bouajila supplementary material

Bouajila supplementary material 1

Download Bouajila supplementary material(File)
File 13.5 KB
Supplementary material: File

Bouajila supplementary material

Bouajila supplementary material 2

Download Bouajila supplementary material(File)
File 2.1 MB