Chronic cerebrospinal venous insufficiency (CCSVI) has been described as a venous condition with abnormal flow in extracranial and intracranial veins.Reference Zamboni, Galeotti and Menegatti 1 CCSVI, as evaluated by ultrasound, has been hypothesized to be associated with multiple sclerosis (MS), possibly even causing MS.Reference Zamboni, Galeotti and Menegatti 1 Five venous characteristics (often referred to as criteria) were recommended to evaluate CCSVI: criterion 1 evaluates extracranial reflux in the internal jugular or vertebral veins in sitting and supine positions; criterion 2 assesses reflux in the deep cerebral veins; criterion 3 assesses proximal internal jugular vein stenosis; criterion 4 assesses lack of flow in the internal jugular or vertebral veins in sitting and supine positions; and criterion 5 assesses reverted postural control of the main cerebral venous outflow pathway.Reference Zamboni, Galeotti and Menegatti 1
Subsequent to the initial reports by Zamboni et al, prevalence studies of CCSVI in MS have reported conflicting results.Reference Zivadinov, Marr and Cutter 2 - Reference Tromba, Blasi, Vestri, Kiltzanidi, Tartaglia and Redler 4 Importantly, some studies have found a very low prevalence of CCSVI,Reference Doepp, Paul, Valdueza, Schmierer and Schreiber 5 - Reference Rodger, Dilar and Dwyer 8 suggesting that the ultrasound assessments in those studies were conducted very differently from the original reports.Reference Valdueza, Doepp and Schreiber 9 We assessed the prevalence of CCSVI in both MS and non-MS populations, utilizing standardized ultrasound methodology and blinded evaluators.
Methods
Using an Institutional Review Board-approved protocol, MS and non-MS controls were evaluated for CCSVI. Subjects with a definite diagnosis of MS, aged 21- 65 years were invited to participate in this study at the Mellen Center, Cleveland Clinic, Cleveland, Ohio, USA. Age matched healthy controls were recruited from the caregiver population and controls with other neuro-inflammatory disorders were recruited from neurologic clinics at the Cleveland Clinic. All ultrasounds were conducted using a Biosound MyLab25Gold, which included traditional trans-cranial Doppler (TCD) and Quality Doppler Profiles (QDP) technology. The Biosound ultrasound machine is capable of high resolution B-mode, which is used to evaluate stenoses in proximal internal jugular veins, (criterion 3).The Biosound’s QDP technology is specifically used to assess reflux in the deep cerebral veins (criterion 2).Reference Zamboni, Galeotti and Menegatti 1 Prior to the study, two sonographers obtained formal training in CCSVI assessments using the BioSound machine, 10 and ultrasound methodology was further standardized to reduce ambiguity. All sonographers hold Registered Vascular Technologist (RVT) credentials. Sonographers were blinded to diagnosis, including the use of separate research staff to position the subject prior to the arrival of the sonographer.
The internal jugular, vertebral, and deep cerebral veins were assessed and measured in both supine and sitting positions. Based upon previous publications, two interpretationsReference Zamboni, Galeotti and Menegatti 1 , Reference Zivadinov, Marr and Cutter 2 of CCSVI criteria were utilized: Narrow Criteria, which did not include either B-mode intraluminal abnormalities (criterion 3) or QDP technology for deep vein reflux (criterion 2); and Broad Criteria, which included both of these.Reference Kim, Diaconu and Fox 11 The Broad Criteria, in fact, have been recently recommended by the International Society of NeuroVascular Disease for CCSVI diagnosis.Reference Zivadinov, Bastianello and Dake 12 All ultrasounds were over-read by a Registered Physician in Vascular Interpretation (EK or ML), who was also blinded to MS diagnosis.
Based upon the original Zamboni report of 100% sensitivity and 100% specificity of CCSVI, sample size was estimated at n=15 per group to replicate those observations. We increased the original sample size to 120 (80 MS and 40 non-MS controls) to have a 90% power to detect an absolute difference of 35% in diagnostic classification (i.e. 30% positive in controls and 65% positive in MS subjects; Chi-square with continuity correction, α=0.05, 2-tailed). Based upon several reports finding no association of CCSVI with MS, an interim futility analysis was conducted after 61 of the anticipated 120 subjects were enrolled. That interim analysis found that further enrollment was unlikely to alter the group differences observed to date.
Results
We enrolled 61 MS subjects (4 CIS, 28 RRMS, 19 SPMS and 10 PPMS; 42 females; mean age 53.84±9.51 years) and 20 non-MS controls (15 healthy subjects and 5 with other neurological diseases; 10 females; mean age 52.21±11.25 years).
The incidence of subjects meeting CCSVI criteria was determined using two interpretations of the ultrasound assessments, which differed in the way criteria 2 and 3 were analyzed. For criterion 2, the narrow interpretation used TCD to assess deep cerebral vein reflux whereas the broad interpretation used QDP. For criterion 3, the narrow interpretation used only B-mode luminal stenosis (<0.30 cm2) as a measure whereas, the broad interpretation included other B-mode abnormalities (e.g. flap or septum) as well.
Using Narrow Criteria, the incidence of subjects meeting two or more CCSVI criteria was 20.0% in controls and 21.3% in MS (Fisher exact test, p=0.99; Figure 1A). Using Broad Criteria, the incidence of subjects meeting two or more CCSVI was 40% in controls and 36.1% in MS (Chi-square test, p=0.75; Figure 1A). Using either criteria, there was no significant difference in CCSVI between MS and controls. In both MS and control groups, there was almost a doubling of the proportion of subjects meeting overall CCSVI definition when using the Broad Criteria. Similarly, there was no significant difference in the proportion of MS and control subjects that met any of the individual ultrasound criteria (Figure 1B).
Discussion
Using blinded sonographers specifically trained in CCSVI assessments, as well as QDP technology, we observed no significant difference in prevalence of CCSVI between MS and non-MS subjects (Figure 1A). Regardless of whether the more liberal Broad Criteria or the restrictive Narrow Criteria were used, the proportion of subjects meeting two or more CCSVI criteria was the same in both MS and non-MS controls (Figure 1A).
Our study adds to the accumulating evidence of contemporary, independent studies demonstrating no association between MS and the vascular condition called CCSVI. Baretto et alReference Barreto, Brod and Bui 13 found a CCSVI prevalence of 3.88% among 200 MS patients and 7.14% among non-MS controls. Traboulsee et al found a CCSVI prevalence of 44% among 79 MS patients and 45% among 43 non-MS controls.Reference Traboulsee, Knox and Machan 14 Costello et al used both extracranial Doppler ultrasonography and magnetic resonance venography to test the CCSVI hypothesis and found no differences in CCSVI prevalence between patients and controls.Reference Costello, Modi and Lautner 15 In the largest study to date, Comi et al found a CCSVI prevalence of 3.26% among 1165 MS patients and 2.13% among 376 non-MS controls.Reference Comi, Battaglia and Bertolotto 16
As we have reported previously, different tools to assess for CCSVI and different interpretations of CCSVI criteria can alter the proportions of subjects meeting CCSVI criteria. The original description of CCSVI utilized the new Biosound MyLab25Gold ultrasound, which utilizes Quality Doppler Profiles (QDP) technology for assessment of flow in the deep cerebral veins. Due to limited availability of the Biosound platform, many subsequent CCSVI studies have utilized TCD instead. Our study highlights the difference in sensitivity between QDP and TCD; 14/81 (17.3%) subjects met Criterion 2 using QDP, while 0/81 (0%) met Criterion 2 using TCD. Similarly, Criterion 3 was met in 50/81 (61.7%) using Narrow Criteria, but 64/81 (79%) using Broad Criteria (Figure 1B). Our observations provide one explanation for the vastly different incidence of CCSVI in healthy controls (and people with MS) among different studies. Some studies found a prevalence of 0-2% in non-MS controls,Reference Doepp, Paul, Valdueza, Schmierer and Schreiber 5 - Reference Rodger, Dilar and Dwyer 8 while others found a prevalence of 22.7-45% in non-MS controls.Reference Traboulsee, Knox and Machan 14 , Reference Zivadinov, Marr and Cutter 17 , Reference Leone, Raymkulova and Naldi 18 These dramatic differences are most certainly due to differences in how the CCSVI ultrasound assessments were conducted and interpreted.
The original protocol for ultrasound assessment of CCSVI has been modified over time. The International Society for NeuroVascular Disease published updated methodology in 2011Reference Nicolaides, Morovic, Menegatti, Viselner and Zamboni 19 , Reference Zamboni, Morovic, Menegatti, Viselner and Nicolaides 20 and then again in 2014.Reference Zivadinov, Bastianello and Dake 12 The change in ultrasound assessments for CCSVI over time and the differences in ultrasound technologies (for example, trans-cranial Doppler and Quality Doppler Profiles technologies) likely contributed to the differences in results from different investigational teams. Our observations highlight the importance of standardizing assessments and their interpretations when new techniques and technologies are introduced.
Unlike the initial unblinded assessments of CCSVI,Reference Zamboni, Galeotti and Menegatti 1 , Reference Al-Omari and Rousan 21 our study was conducted with careful attention to blinding. Each subject (MS and non-MS controls) was brought into the ultrasound examination room and positioned by a separate research staff, before the arrival of the sonographer. Thus, sonographers were blinded to the physical impairments of the study subjects. Each ultrasound study was then over-read at a later time by an independent, blinded physician certified in vascular interpretations. The absence of such rigorous blinding is a possible explanation for some of the previous studies that found associations of CCSVI with MS. Some studies that found a difference in CCSVI prevalence between MS and non-MS controls report having been conducted blinded, although the details of the blinding were typically not described.Reference Zamboni, Galeotti and Menegatti 1 , Reference Zivadinov, Marr and Cutter 17 Blinding may explain some of the differences in results between different studies but seems not to explain all the differences.
Other factors that may influence ultrasound assessments for CCSVI include hydration. We found that rehydration after mild, overnight dehydration can have a significant impact on CCSVI ultrasound assessment, with five of seven subjects no longer meeting CCSVI criteria following rehydration.Reference Diaconu, Fox and Grattan 22 People with MS often prefer to be mildly dehydrated because of neurogenic bladder dysfunction and this may have contributed to some studies finding an increased prevalence of CCSVI among people with MS.
In summary, our observations do not support an increased prevalence of CCSVI in MS and suggest against a pathogenic role of CCSVI in MS. Combined with other negative association studies of CCSVI with MS, further study of CCSVI in MS appears to be unwarranted.
Acknowledgements
Supported by the National MS Society (RC 1004-A-5).
Contributions
Dr. Fox: study concept and design, study supervision and coordination, analysis and interpretation of data, obtained funding, manuscript preparation; Dr. Diaconu: study conduct and coordination, analysis and interpretation of data, manuscript review; Ms. Baus, Ms. Grattan, Dr. Katzan and Mr. Raber: study conduct, manuscript review; Dr. Rae-Grant: study design, study supervision and coordination, interpretation of data, manuscript review.
Ms. Lee: statistical analysis, manuscript review; Dr. Ramesh: study conduct and coordination, data analysis, manuscript preparation; Dr. Lu: study supervision, analysis and interpretation of data, manuscript review; Dr. Kim: study supervision, analysis and interpretation of data, manuscript review.
Disclosures
Robert Fox has the following disclosures: Allozyne, Consultant, Consulting fees; Anavir, Consultant, Consulting fees; Biogen-Idec, Consultant and Advisory committee, Consulting fees, Novartis, Consultant and Advisory committee, Consulting fees, Questcor, Consultant, Consulting fees, Teva, Consultant, Consulting fees, Xenoport, Consultant, Consulting fees.
Esther S.H. Kim has the following disclosures: Phillips Ultrasound, Consultant, Consulting fees; GE, Researcher, Grant funding.
Claudiu Diaconu, Leasa Baus, Alia Grattan, Irene Katzan, Jar-Chi Lee, Larry Raber, Alexander Rae-Grant, Sneha Ramesh, and Mei Lu do not have anything to disclose.