X-Ray Fluorescence Analysis of Alloy and Stainless Steels Using a Mercuric Iodide Detector*

Published online by Cambridge University Press:  06 March 2019

Warren C. Kelliher
Affiliation:
NASA Langley Research Center Hampton, Virginia
W. Gene Maddox
Affiliation:
NASA Langley Research Center Hampton, Virginia
Get access

Extract

Energy dispersive x-ray fluorescence (XRF) spectrometry has been used extensively for some time now to do accurate and rapid analysis of a variety of samples. Most XRF Systems today use cryogenically cooled Si(Li) detectors to obtain the resolution needed for analysis of samples containing several elements. The need for the cryogenic coolant results in these XRP systems being rather large and not readily adaptable to portable devices. Detectors that require no cooling, or at least require only cooling obtainable by electrical weans, offer a definite advantage over cryogenically cooled detectors for use in portable devices. Mercuric iodide (HgI2) detectors are one type of such room-temperature detectors. The major disadvantage of any room-temperature detector has been the poor eneygy resolution associated with them.

Type
VII. XRF Techniques, Instrumentation and Mathematical Models
Copyright
Copyright © International Centre for Diffraction Data 1987

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

*

Work supported by NASA contract NCC1-92.

References

1. Dabrovishi, k.J. and Huth, G.C., “Toward the Energy Resolution Limit of Mercuric Iodide in Room Température Low Energy Spectrometry”, IEEE transactions on Huclear Science, Vol. N5-25, No. 1, February, 1978.Google Scholar
2. Dabrowski, A.J., Huth, G.C., and Singh, M., “Characteristics X-Ray Spectra of Sodium and Magnesium Measured at Room Temperature Using Mercuric Iodide Detectors”, Applied Physics Letters, 33(2), July 15, 1978.Google Scholar
3. Faile, S.P., Dabrowski, A.J., Huth, G.G. and Iwanczyk, J.S., “Mercuric Iodide (Hgl2) Platelets for X-ray Spectroscopy produced by Polymer Controlled GrowtTn”, Journal of Crystal Growth, 50 (1980) pp. 752755.Google Scholar
4. Leyden, D.E., Harding, A-R., and Goldbach, K., “Applications of Room Temperature Energy Dispersive X-ray Spectrometry Using a Mercuric Iodide Detector”, Advances in X-ray Analysis, Vol.27, pp 52 7 (1984).Google Scholar
5. Rasberry, S.D. and Heinrich, K.E. J., Anal. Chem., 46, 81, (1974).Google Scholar