Hostname: page-component-78c5997874-fbnjt Total loading time: 0 Render date: 2024-11-20T05:46:42.607Z Has data issue: false hasContentIssue false

INDEX, A Program to Reconcile Powder Diffractograms

Published online by Cambridge University Press:  06 March 2019

Tommy Horn
Affiliation:
Philips Electronic Instruments, Inc., 85 McKee Drive, Mahwah, N. J. 07430
Ron Jenkins
Affiliation:
Philips Electronic Instruments, Inc., 85 McKee Drive, Mahwah, N. J. 07430
Joshua Ladell
Affiliation:
Philips Laboratories, Briarcliff Manor, N.Y. 10510
Get access

Abstract

This paper describes an interactive computer program, INDEX, which was written at Philips Laboratories as part of the software development effort for the APD 3600: Automated Powder Diffractometer. This program reconciles the differences between calculated and observed powder diffractogram “d-spacings” by unit cell parameters refinement and/or correction of observed lines for “significant“ systematic errors. The reconciliation procedures, described below, yield a set of residual differences which may be due to x-ray photon statistics, random gear imperfections, or minor instrumental aberrations. Lattice parameters accuracies of 4-5 parts per 104 can b e obtained routinely on powder diffractometers when systematic effects have been taken into account. The interactive nature of INDEX permits intervention at critical stages where it is most beneficial with a minimal number of keystrokes.

Type
VI. XRD Search/Match Procedures and Automation
Copyright
Copyright © International Centre for Diffraction Data 1981

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

(1) Rxetveld, H.M., “A Profile Refinement Method for Nuclear and Magnetic structures”, J. Appl. Cryst. 2, 6571 (1969)Google Scholar
(2) Malmros, G. and Thomas, J.O., “Least-Squares Structure Refinement Based on Profile Analysis of Powder Film Intensity Data Measured on an Automatic Microdensitometer”, J. Appl. Cryst. 10, 711 (1977)Google Scholar
(3) Young, R. A., Mackie, P.E. and von Dreele, R. B., “Application of the Pattern-Fitting Structure∼Refinement Method to X-ray Powder Diffractometer Patterns”, J. Appl. Cryst. 10, 262269 (1977)Google Scholar
(4) Runge, C., “Analysis of Crystal Structures by X-rays”, Z. Zeits 18, 509513 (1917)Google Scholar
(5) Ito, T., “A General Powder X-ray Photograptiy”, Mature, 164, 755 (1949); “X-ray Studies on Polymorphism” Maruzen, Tokyo p. 187 (1950)Google Scholar
(6) deWolff, P.M., “A Simplified Criterion for the Reliability of a Powder Pattern Indexing”, J. Appl. Cryst., 1, 108113 (1968).Google Scholar
(7) Visser, J. W., “A Fully Automated Program for Finding the Unit Cell from Powder Data”, J. Appl. Cryst., 2, 8995 (1969)Google Scholar
(8) Werner, P.E., “Trial and Error Computer Method for Indexing of Unknown Powder Patterns”, Z, Kristallogr., 120, 375387 (1964)Google Scholar
(9) Louer, D. and Louer, M., “Methode d’ Essais et. Erreurs pour X’ldexation Automatique des Diagrammes de Poudre”, J. Appl. Cryst., 5, 271275 (1972).Google Scholar
(10) Shirley, R., “Recent Advances in Determining Unknown Cells from Powder Diffractometer Data”, Acta Cryst., A31, S197 (1975).Google Scholar
(11) Shirley, R., “Indexing Powder Diagrams”, Crystallographic Computing, Proceedings of 1978 Summer School, Delft Univ. Press and Oosthoeks.Google Scholar
(12) Schreiner, W. M., Surdukowski, C., Jenkins, R. and VillSmizar, C., “Systematic and Random Diffractometer Errors Relevant to Phase Identification”, in press (1981)Google Scholar
(13) Smith, G.S. and Snyder, R.L., “A Criterion for Rating Powder Diffraction Patterns and Evaluating the Reliability of Powder Pattern Indexing”, J. Appl. Cryst. 12, 60 (1969).Google Scholar
(14) International Tables for X-ray Crystallography,. Vol. 1, Kynocb Press Google Scholar