Hostname: page-component-586b7cd67f-rdxmf Total loading time: 0 Render date: 2024-11-29T16:57:17.428Z Has data issue: false hasContentIssue false

FESEM and Cryo-Techniques in the Study of Marine Diatom A. Longipes

Published online by Cambridge University Press:  02 July 2020

Ya Chen
Affiliation:
Integrated Microscopy Resource (IMR), University of Wisconsin-Madison, Madison, WI53706
Yan Wang
Affiliation:
Department of Biological Sciences, Michigan Technological University, Houghton, MI49931
Michael Gretz
Affiliation:
Department of Biological Sciences, Michigan Technological University, Houghton, MI49931
Get access

Extract

Field emission scanning electron microscopy (FESEM) provides a direct view of a biological sample with high spacial resolution. Combining FESEM with cryo-techniques, macromolecular structures have been obtained from single SEM image successfully (Hermann & Müller, 1992; Chen et al., 1995, 1997). This protocol is now applied to study the extracellular matrix of the diatom A. longipes.

Stalk, which is originated from the terminal region of diatom cells, consists of 3 regions: a surfaceadhered pad, a shaft that separates the cell from the substratum, and a ring-like collar (Fig. 1). Investigating the structure and function of the stalk will help to understand the adhesion and interaction of diatom with the external environment. The extracellular matrix of diatom is highly hydrated, it is difficult to preserve them for EM. It will be easily extracted and collapse during specimen preparation (e.g. fixation, dehydration). In order to preserver the stalk structures close to their native condition and observer them with high fidelity, cryo-preparation techniques are implemented. Cryo-technique is widely used in the plant biology. However, to our knowledge, it has not been used in the diatom research.

Type
Cryotechniques, Immunocytochemistry, and Electron Microscopy I. Molecular Approach
Copyright
Copyright © Microscopy Society of America

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Chen, Y., Centonze, V.E., Verkhovsky, A. and Borisy, G.G., J.Microsc., 179(1995)67-76.CrossRefGoogle Scholar
2.Chen, Y., Zardi, L. and Peters, D.M., Scanning, 19(1997)349355.CrossRefGoogle ScholarPubMed
3.Hermann, R. and Müller, M., Scanning Microscopy, 5(1991)653664.Google Scholar
4.Moor, H.Cryotechniques in Biological Electron Microscopy. Springer-Verlag, New York (1987)Google Scholar
5.Wang, YLu, J.Mollet, J.C.Gretz, M.R.Hoagland, K.D.Plant Physiol., 113 (1997)10711080.CrossRefGoogle Scholar
6.Wang, Y.Wustman, B.A., Chen, Y., Lavin, C. and Gretz, M.R.Microscopy and Microanalysis, 4(1998)11341135.CrossRefGoogle Scholar
7. This work was supported by NIH Grant DRR-0570 to the Integrated Microscopy Resource (IMR), University of Wisconsin-Madison and office of Naval Research Grants to Michigan Technological University.Google Scholar